Curvature correction of retinal OCTs using graph-based geometry detection
Authors:
- 11 April 2013
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 58 (9) , 2925-2938
Abstract
In this paper, we present a new algorithm as an enhancement and preprocessing step for acquired optical coherence tomography (OCT) images of the retina. The proposed method is composed of two steps, first of which is a denoising algorithm with wavelet diffusion based on a circular symmetric Laplacian model, and the second part can be described in terms of graph-based geometry detection and curvature correction according to the hyper-reflective complex layer in the retina. The proposed denoising algorithm showed an improvement of contrast-to-noise ratio from 0.89 to 1.49 and an increase of signal-to-noise ratio (OCT image SNR) from 18.27 to 30.43 dB. By applying the proposed method for estimation of the interpolated curve using a full automatic method, the mean ± SD unsigned border positioning error was calculated for normal and abnormal cases. The error values of 2.19 ± 1.25 and 8.53 ± 3.76 µm were detected for 200 randomly selected slices without pathological curvature and 50 randomly selected slices with pathological curvature, respectively. The important aspect of this algorithm is its ability in detection of curvature in strongly pathological images that surpasses previously introduced methods; the method is also fast, compared to the relatively low speed of similar methods.Keywords
This publication has 25 references indexed in Scilit:
- Automated Segmentation of the Cup and Rim from Spectral Domain OCT of the Optic Nerve HeadInvestigative Ophthalmology & Visual Science, 2009
- Detecting intrinsic slow variables in stochastic dynamical systems by anisotropic diffusion mapsProceedings of the National Academy of Sciences of the United States of America, 2009
- Thickness Profiles of Retinal Layers by Optical Coherence Tomography Image SegmentationAmerican Journal of Ophthalmology, 2008
- Characterization of Outer Retinal Morphology with High-Speed, Ultrahigh-Resolution Optical Coherence TomographyInvestigative Ophthalmology & Visual Science, 2008
- Towards quantitative analysis of retinal features in optical coherence tomographyMedical Engineering & Physics, 2006
- Macular Segmentation with Optical Coherence TomographyInvestigative Ophthalmology & Visual Science, 2005
- Quantitative Thickness Measurement of Retinal Layers Imaged by Optical Coherence TomographyAmerican Journal of Ophthalmology, 2005
- Retinal thickness measurements from optical coherence tomography using a Markov boundary modelIEEE Transactions on Medical Imaging, 2001
- Optical Coherence Tomography of the Human RetinaArchives of Ophthalmology (1950), 1995
- A note on two problems in connexion with graphsNumerische Mathematik, 1959