Simulation‐Informed Evaluation of Microvascular Parameter Mapping for Diffusion MR Imaging of Solid Tumours
Authors:
- Anna Kira VoronovaAVAnna Kira Voronova
- Olivia PriorOPOlivia Prior
- Athanasios GrigoriouAGAthanasios Grigoriou
- Francesc SalvàFSFrancesc Salvà
- Elena ElezEEElena Elez
- Roser Sala‐LlonchRSRoser Sala‐Llonch
- Marco PalomboMPMarco Palombo
- Els FieremansEFEls Fieremans
- Dmitry S. NovikovDNDmitry S. Novikov
- Raquel Perez‐LopezRPRaquel Perez‐Lopez
- Francesco GrussuFGFrancesco Grussu
Open Access
- 7 March 2026
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 96 (1) , 387-402
Abstract
Purpose: We aim to inform the design of new diffusion MRI (dMRI) approaches for microvasculature quantification that enhance the biological specificity of imaging towards cancer. Methods: We adopted simulation‐informed modelling of the vascular dMRI signal. We synthesised signals from 1500 synthetic vascular networks, for a variety of protocols (flow‐compensated [FC], non‐compensated [NC], hybrid), featuring different samplings and diffusion times. We estimated the number of independent, recoverable signal degrees of freedom in presence of noise (signal‐to‐noise ratio of 5), and ranked 12 microvascular metrics depending on the quality of their estimation. Lastly, we demonstrated the feasibility of estimating the top‐ranking metrics on 3T dMRI of a healthy volunteer and of a metastatic colorectal cancer (CRC) patient. Results: Both NC and FC synthetic vascular signals exhibited complex behaviour as, for example, non‐zero kurtosis and diffusion time dependence. Two independent degrees of freedom appeared recoverable from directionally‐averaged vascular signals (SNR of 5). Mean volumetric flow rate and an Apparent Network Branching (ANB) index maximised correlations between ground truth and estimated values in silico. In the patient, both and detected re‐vascularisation after 3 months of targeted therapy against liver metastases, consistently with Intra‐Voxel Incoherent Motion (IVIM) metrics. Conclusions: Simulation‐based modelling of the vascular dMRI signal suggests and as the most promising metrics for tissue microvasculature characterisation. Their estimation in vivo appears feasible to capture general trends, and demonstrates contrasts that are biologically plausible, encouraging their usage in future studies.Keywords
Funding Information
- Agència de Gestió d'Ajuts Universitaris i de Recerca (2023PROD00178)
- Agència de Gestió d'Ajuts Universitaris i de Recerca (SGR‐Cat2021)
- Fundación Científica Asociación Española Contra el Cáncer (PRYCO211023SERR)
- UK Research and Innovation (MR/T020296/2)
- CRIS Cancer Foundation (TALENT19‐05)
- Prostate Cancer Foundation (18YOUN19)
- Fundación Fero
- Instituto de Salud Carlos III (PI18/01395)
- Instituto de Salud Carlos III (PI21/01019)
- Agencia Estatal de Investigación (CEX2020‐001024‐S/AEI/10.13039/501100011033)
- Agencia Estatal de Investigación (PRE2022‐102586)
- 'la Caixa' Foundation (CaixaResearch Advanced Oncology Research Program)
- 'la Caixa' Foundation (LCF/BQ/PR22/11920010)
- Fundación BBVA (89/2017)
- Fundación Cellex
This publication has 46 references indexed in Scilit:
- Enhancing Tumor Microstructural Quantification With Machine Learning and Diffusion‐Relaxation MRIJournal of Magnetic Resonance Imaging, 2024
- Advanced Diffusion‐Weighted MRI for Cancer Microstructure Assessment in Body Imaging, and Its Relationship With HistologyJournal of Magnetic Resonance Imaging, 2023
- Intravoxel Incoherent Motion Magnetic Resonance Imaging in Skeletal Muscle: Review and Future DirectionsJournal of Magnetic Resonance Imaging, 2021
- Gibbs‐ringing artifact removal based on local subvoxel‐shiftsMagnetic Resonance in Medicine, 2015
- Diffusion MRI noise mapping using random matrix theoryMagnetic Resonance in Medicine, 2015
- Flow‐compensated intravoxel incoherent motion diffusion imagingMagnetic Resonance in Medicine, 2014
- Combined intravoxel incoherent motion and diffusion tensor imaging of renal diffusion and flow anisotropyMagnetic Resonance in Medicine, 2014
- Evaluation of hepatic focal lesions using diffusion‐weighted MR imaging: Comparison of apparent diffusion coefficient and intravoxel incoherent motion‐derived parametersJournal of Magnetic Resonance Imaging, 2013
- Design of multishell sampling schemes with uniform coverage in diffusion MRIMagnetic Resonance in Medicine, 2013
- A general framework for experiment design in diffusion MRI and its application in measuring direct tissue‐microstructure featuresMagnetic Resonance in Medicine, 2008