Geometrical Enhancements for Abdominal Aortic Stent-Grafts
- 1 October 2008
- journal article
- Published by International Society of Endovascular Specialists in Journal of Endovascular Therapy
- Vol. 15 (5) , 518-529
Abstract
Purpose: To compare the function of 2 stent-graft designs for endovascular abdominal aortic aneurysm repair. Methods: Computational fluid dynamics was used to investigate the performance of a conventional stent-graft versus one with a novel tapered configuration (equal area ratios at the inlet and bifurcation). Idealized geometries (uniplanar) were formed first for both devices. To mimic the clinical setting with pulsatile blood flow, a realistic model (multiplanar) was created for the conventional stent-graft based on computed tomography scans from 3 patients with different aortic geometries. A similar model was created for the tapered stent-graft by mimicking the deployment of the conventional stent-graft through its centerline. Results: The tapered stent-graft model demonstrated reduced secondary flow vortices and wall shear stresses in the iliac limbs compared to the conventional graft in the idealized scenario. The drag forces in the idealized models were similar for both designs, though the tapered stent-graft showed a 4% reduction. Flow was split more evenly between the tapered stent-graft limbs in the realistic scenario. Conclusion: The novel tapered design reduced flow velocities and secondary flows due to its smooth trunk-to-limb transition, while also splitting the flow between the iliac limbs more evenly. In multiplanar models, the out-of-plane curvature was the greatest cause of skewed flow, which reduced the benefits of the tapered stent-graft.Keywords
This publication has 24 references indexed in Scilit:
- A Review of the In Vivo and In Vitro Biomechanical Behavior and Performance of Postoperative Abdominal Aortic Aneurysms and Implanted Stent-GraftsJournal of Endovascular Therapy, 2008
- Abdominal aortic aneurysmThe Lancet, 2005
- Abdominal Aortic Aneurysm:Journal of Interventional Cardiology, 2004
- Effect of improved endograft design on outcome of endovascular aneurysm repairJournal of Vascular Surgery, 2004
- Flow patterns in an endovascular stent-graft for abdominal aortic aneurysm repairJournal of Biomechanics, 2004
- Stent-graft design: the good, the bad and the uglyCardiovascular Surgery, 2001
- Model studies of the flow in abdominal aortic aneurysms during resting and exercise conditionsJournal of Biomechanics, 1999
- Numerical study on the effect of steady axial flow development in the human aorta on local shear stresses in abdominal aortic branchesJournal of Biomechanics, 1999
- Immediate and late explantation of endovascular aortic grafts: The Endovascular Technologies experienceJournal of Vascular Surgery, 1999
- Transfemoral Intraluminal Graft Implantation for Abdominal Aortic AneurysmsAnnals of Vascular Surgery, 1991