Reducing Radiation Exposure in the Electrophysiology Laboratory: It is More Than Just Fluoroscopy Times!
- 9 December 2014
- journal article
- research article
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 38 (1) , 136-145
Abstract
Background To exposure in patients undergoing cardiac electrophysiology (EP) ablation. This included the use of a “very low” dose protocol, and the impact of angulations and patient body mass index (BMI) on radiation dose as a mean to reduce exposure. Methods A total of 212 retrospective patient data sets were collected during EP ablation procedures on a biplane fluoroscopy system. Dose metrics were computed based on dose‐area product (DAP) measured by the system for each x‐ray acquisition. Results Dose baselines of different ablation procedures were established as DAP and DAP per hour, with respect to patient BMI. The use of a “very low dose” protocol reduced exposure by 62% while providing adequate image quality. With approximate left anterior oblique (LAO) 50° and right anterior oblique (RAO) 30°, DAP and DAP rate were significantly higher in LAO compared to RAO (11.2 [4.8–25.3] Gy·cm2 vs 5.28 [2.9–11.1] Gy·cm2 and 74.0 [38.2–136.1] Gy·cm2/h vs 25.0 [16.4–44.1] Gy·cm2/h, respectively; P < 0.001). DAP and DAP rate were also significantly higher in patients with BMI > 30 vs BMI ≤ 30 (34.2 [22.3–58.7] Gy·cm2 vs 12.4 [6.0–26.9] Gy·cm2 and 84.9 [68.1–120.4] Gy·cm2/h vs 34.2 [21.7–52.9] Gy·cm2/h, respectively; P < 0.001). Conclusion Protocol setting, system angulation, and BMI, in particular, wider angulation in LAO compared to RAO plane, exposes patients to significant higher radiation doses. Obese patients in standard LAO plane receive six times the radiation dose of nonobese patients in RAO.Keywords
This publication has 18 references indexed in Scilit:
- Entrance Skin Dose during Radiofrequency Catheter Ablation for Tachyarrhythmia: A Multicenter StudyPacing and Clinical Electrophysiology, 2011
- Improving safety in the electrophysiology laboratory using a simple radiation dose reduction strategy: a study of 1007 radiofrequency ablation proceduresHeart, 2010
- Obesity Is a Major Determinant of Radiation Dose in Patients Undergoing Pulmonary Vein Isolation for Atrial FibrillationJACC, 2007
- The Impact of CT Image Integration into an Electroanatomic Mapping System on Clinical Outcomes of Catheter Ablation of Atrial FibrillationJournal of Cardiovascular Electrophysiology, 2006
- Characterization of Conduction Recovery Across Left Atrial Linear Lesions in Patients with Paroxysmal and Persistent Atrial FibrillationJournal of Cardiovascular Electrophysiology, 2006
- Electrical isolation of pulmonary veins in patients with atrial fibrillation: reduction of fluoroscopy exposure and procedure duration by the use of a non-fluoroscopic navigation system (NavX®)EP Europace, 2006
- Patient and staff radiation dosimetry during cardiac electrophysiology studies and catheter ablation procedures: a comprehensive analysisEP Europace, 2006
- Reduction of fluoroscopy exposure and procedure duration during ablation of atrial fibrillation using a novel anatomical navigation system†European Heart Journal, 2005
- ACCF/AHA/HRS/SCAI clinical competence statement on physician knowledge to optimize patient safety and image quality in fluoroscopically guided invasive cardiovascular proceduresJACC, 2004
- Identification of less-irradiating tube angulations in invasive cardiologyJACC, 2004