Abstract
Background: The management of patients with slipped capital femoral epiphysis (SCFE) requires imaging diagnostics of good quality and accurate measurement of the degree of slippage. In Sweden, three different radiological methods are commonly used: the calcar femorale method; the Billing method; and the Head-shaft angle described by Southwick. Purpose: To evaluate whether any of the three most common methods used in Sweden to measure the slip angle was more useful and reproducible than the others. Material and Methods: Two experienced orthopaedists measured the slip angle in preoperative hip radiographs. Intra- and inter-observer variability between the two experienced observers and the reported value by clinicians who treated the child with SCFE was evaluated. Results: The intraclass correlation coefficient (ICC) confidence interval (CI) between the two experienced observers and the reporting clinicians overlapped for the three methods. In 37% of the cases, the difference was more than 5° between the experienced observers’ measurement and the reported value by clinicians. The two experienced orthopaedists' intra- and inter-observer variability was low. Conclusion: The observer's experience is more important than the method of choice when measuring the slip angle in SCFE. The research group recommends the calcar femorale method due to its feasibility on the versatile and commonly used frog leg lateral view.Keywords
Funding Information
- Futurum - Akademin för Hälsa och Vård, Region Jönköpings läns
- Erik och Angelica Sparres forskningsstiftelse
This publication has 11 references indexed in Scilit:
- Outcomes after slipped capital femoral epiphysis: A population-based study with three-year follow-upJournal of Children's Orthopaedics, 2018
- Good inter- and intraobserver reliability for assessment of the slip angle in 77 hip radiographs of children with a slipped capital femoral epiphysisActa Orthopaedica, 2017
- Slipped capital femoral epiphysis: a population-based studyBMC Musculoskeletal Disorders, 2017
- A nationwide cohort study of slipped capital femoral epiphysisArchives of Disease in Childhood, 2017
- Multiplanar CT assessment of femoral head displacement in slipped capital femoral epiphysisPediatric Radiology, 2013
- Intra- and inter-observer repeatability of radiographic measurements for previously slipped capital femoral epiphysis at skeletal maturityActa Radiologica, 2013
- Reliable X-ray diagnosis of slipped capital femoral epiphysis by combining the conventional and a new simplified geometrical methodPediatric Radiology, 2002
- Unstable Slipped Capital Femoral EpiphysisJournal of Pediatric Orthopaedics, 2001
- Effect of Femur Position on the Angular Measurement of Slipped Capital Femoral EpiphysisJournal of Pediatric Orthopaedics, 2001
- Osteotomy through the Lesser Trochanter for Slipped Capital Femoral EpiphysisJournal of Bone and Joint Surgery, 1967