An iterative method for reference pattern selection in high resolution electron backscatter diffraction (HR-EBSD)

Authors:
  • AKAbdalrhaman Koko
    Abdalrhaman Koko
  • AWAngus J. Wilkinson
    Angus J. Wilkinson
  • TMT. James Marrow
    T. James Marrow

Abstract
The reference pattern selected for high (angular) resolution electron backscatter diffraction (HR-EBSD) can significantly affect the precision of strain mapping due to the conditions at the reference point. The effect of the selected reference on HR-EBSD strain maps has been studied for in situ observations of the straining of body centre cubic and face centre cubic ductile metals (ferrite and austenite in duplex stainless steel) and single crystal silicon. An empirical relation was identified between the cross-correlation parameter and angular error. This relationship guides a novel iterative method to objectively locate the least deformed reference pattern, improving the calculated field precision.