Cardiac implantable electronic device infection in the cardiac referral center in Thailand: incidence, microbiology, risk factors, and outcomes
Open Access
- 27 September 2018
- journal article
- research article
- Published by Wiley in Journal of Arrhythmia
- Vol. 34 (6) , 632-639
Abstract
Background: Despite the long experience of cardiac implantable electronic device (CIED) implantation in Thailand, epidemiology of CIED infection in Thailand has never been studied.Methods: A retrospective cohort study was conducted at the cardiac referral center in Thailand to investigate incidence of CIED infection and causative organisms between October 2002 and December 2017. A matched case‐control study was performed to determine the factors associated with CIED infection.Results: Incidence of CIED infection was 0.9% with a stable trend during the studied period. There were 54 episodes of CIED infection. The median (interquartile range) age of the patients was 67.5 (53.0‐75.0) years. A total of 29 (53.7%), 18 (33.3%), and 7 (13.0%) were permanent pacemaker, automatic implantable cardioverter‐defibrillator, and cardio‐resynchronization therapy‐related infection, respectively. Gram‐positive cocci were the most common organism (24 episodes, 44.4%). Gram‐negative bacilli were isolated in six episodes (11.1%). About 9.3% were polymicrobial and 35.2% were culture negative. Multivariate analysis showed that previous CIED infection and generator revision procedure were associated with CIED infection (odds ratio [OR] 48.56, 95% confidence interval [CI] 3.72‐633.62; P = 0.003 and OR 19.99, 95% CI 1.28‐333.24; P = 0.033 respectively). Forty (74.1%) cases were cured. Leaving device in situ was the only factor significantly associated with poor outcome (OR 11.40, 95% CI 1.52‐85.73; P = 0.018).Conclusions: In Thailand, while CIED implantation is rising, incidence of CIED infection is stable. Microbiology of CIED infection in Thailand is similar to western countries, albeit a higher proportion of negative culture. Previous CIED infection and generator revision procedure are associated with CIED infection.Keywords
This publication has 39 references indexed in Scilit:
- 16-Year Trends in the Infection Burden for Pacemakers and Implantable Cardioverter-Defibrillators in the United StatesJACC, 2011
- The 11th World Survey of Cardiac Pacing and Implantable Cardioverter‐Defibrillators: Calendar Year 2009–A World Society of Arrhythmia's ProjectPacing and Clinical Electrophysiology, 2011
- Infection after pacemaker implantation: infection rates and risk factors associated with infection in a population-based cohort study of 46299 consecutive patientsEuropean Heart Journal, 2011
- Device‐Related Infection Among Patients With Pacemakers and Implantable Defibrillators: Incidence, Risk Factors, and ConsequencesJournal of Cardiovascular Electrophysiology, 2010
- Contemporary management of and outcomes from cardiac device related infectionsEP Europace, 2009
- Prevalence and risk factors related to infections of cardiac resynchronization therapy devicesEuropean Heart Journal, 2009
- Efficacy of Antibiotic Prophylaxis Before the Implantation of Pacemakers and Cardioverter-DefibrillatorsCirculation: Arrhythmia and Electrophysiology, 2009
- Risk factors and time delay associated with cardiac device infections: Leiden device registryHeart, 2008
- Overview of Nosocomial Infections Caused by Gram-Negative BacilliClinical Infectious Diseases, 2005
- Rapid Identification of Bacteria and Yeast: Summary of a National Committee for Clinical Laboratory Standards Proposed GuidelineClinical Infectious Diseases, 2001