Internal Knee Derangement Assessed with 3-minute Three-dimensional Isovoxel True FISP MR Sequence: Preliminary Study
Authors:
- Sylvain R. DucSDSylvain R. Duc
- Christian W. A. PfirrmannCPChristian W. A. Pfirrmann
- Peter P. KochPKPeter P. Koch
- Marco ZanettiMZMarco Zanetti
- Juerg HodlerJHJuerg Hodler
- 1 February 2008
- journal article
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 246 (2) , 526-535
Abstract
To prospectively evaluate the accuracy of magnetic resonance (MR) imaging of the knee performed by using a three-dimensional (3D) isovoxel sequence involving an acquisition time of approximately 3 minutes, with surgery as the reference standard. The study was institutional review board approved. Written informed consent was obtained from all patients. Thirty knees of 29 patients (14 women, 15 men; mean age, 41 years) were prospectively examined by using a 3D isovoxel true fast imaging with steady-state precession (FISP) sequence with water excitation and secondary multiplanar reformations. All patients underwent arthroscopy within 12 days after true FISP MR imaging. Two blinded readers evaluated the MR images. Accuracy for detection of cartilage defects and anterior cruciate ligament (ACL) and meniscal tears, interobserver agreement, and intermethod agreement were calculated. Overall sensitivity, specificity, and accuracy of isovoxel true FISP imaging for the diagnosis of cartilage defects were 45%, 83%, and 76%, respectively, for reader 1 and 63%, 82%, and 83%, respectively, for reader 2. Averaged (for readers 1 and 2) sensitivity, specificity, and accuracy of isovoxel true FISP imaging were, respectively, 80%, 95%, and 90% for diagnosis of ACL tear; 100%, 82%, and 90% for diagnosis of medial meniscal tear; and 83%, 83%, and 83% for diagnosis of lateral meniscal tear. The standard MR sequences used at the authors' institution had overall sensitivities, specificities, and accuracies of 39%, 83%, and 71%, respectively, for reader 1 and 37%, 85%, and 76%, respectively, for reader 2. Averaged sensitivity, specificity, and accuracy of the standard MR sequences were, respectively, 70%, 100%, and 90% for diagnosis of ACL tear; 96%, 77%, and 85% for diagnosis of medial meniscal tear; and 83%, 77%, and 78% for diagnosis of lateral meniscal tear. The diagnostic performance of knee MR imaging performed by using a 3D water excitation isovoxel true FISP sequence and an imaging time of approximately 3 minutes is comparable to the diagnostic performance of the MR sequences used as standards at the authors' institution.Keywords
This publication has 24 references indexed in Scilit:
- Evaluation of the articular cartilage of the knee joint with vastly undersampled isotropic projection reconstruction steady-state free precession imagingJournal of Magnetic Resonance Imaging, 2006
- Toward single breath‐hold whole‐heart coverage coronary MRA using highly accelerated parallel imaging with a 32‐channel MR systemMagnetic Resonance in Medicine, 2006
- High‐resolution renal MRA: Comparison of image quality and vessel depiction with different parallel imaging acceleration factorsJournal of Magnetic Resonance Imaging, 2006
- Parallel imaging in cardiovascular MRI: methods and applicationsNMR in Biomedicine, 2006
- Accuracy and precision of quantitative assessment of cartilage morphology by magnetic resonance imaging at 3.0TArthritis & Rheumatism, 2005
- Rapid fat‐suppressed isotropic steady‐state free precession imaging using true 3D multiple‐half‐echo projection reconstructionMagnetic Resonance in Medicine, 2005
- Rapid Musculoskeletal Magnetic Resonance Imaging Using Integrated Parallel Acquisition Techniques (IPAT) - Initial ExperiencesRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2003
- Imaging of the articular cartilage in osteoarthritis of the knee joint: 3D spatial‐spectral spoiled gradient‐echo vs. fat‐suppressed 3D spoiled gradient–echo MR imagingJournal of Magnetic Resonance Imaging, 2003
- SENSE: Sensitivity encoding for fast MRIMagnetic Resonance in Medicine, 1999
- Multiplanar Reconstruction in Magnetic Resonance Evaluation of the KneeInvestigative Radiology, 1993