Electrochemically reduced graphene oxide integrated with carboxylated-8-carboxamidoquinoline: A platform for highly sensitive voltammetric detection of Zn(II) ion by screen-printed carbon electrode
Open Access
- 7 February 2025
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 20 (2) , e0315974
Abstract
Zinc has been demonstrated to boost immune response during SAR-CoV-2 infection, where it prevents coronavirus multiplication. Clinical investigations have testified to its beneficial effects on respiratory health and its deficiency may reduce immune function. A highly sensitive detection of Zn(II) ion via differential pulse voltammetry (DPV) utilizing an environmentally friendly modified screen-printed carbon electrode (SPCE) of electrochemically reduced graphene oxide (ErGO) embedded with carboxylated-8-carboxamidoquinoline (CACQ) as Zn(II) chelating ligand. The green CACQ/ErGO-modified SPCE was characterized by spectroscopy techniques, such as Fourier-transform infrared (FTIR) spectroscopy, Raman spectroscopy, and field-emission scanning electron microscopy with energy dispersive X-ray (FESEM-EDX). The modified electrode-solution interface was studied by electrochemical cyclic voltammetry (CV) and DPV methods. The CACQ-modified wrinkled ErGO electrode conferred a large surface-to-volume ratio with multiple binding sites resulting in greater opportunity for multiple dative covalent binding events with Zn(II) via coordination chemistry, and considerably accelerated the electron transfer rate at the electrode surface. The green Zn(II) sensor demonstrated a quick response time (60 s), broad linear range [1 pM-1 μM Zn(II) ion], a limit of detection (LOD) of 0.53 pM, 35 days of storage period (≥80% of its initial response retained), good reproducibility [relative standard deviation (RSD) = 3.4%], and repeatability (RSD = 4.4%). The developed electrode was applied to determine Zn(II) ion concentration in dietary supplement samples, and the results were in good agreement with those obtained from inductively coupled plasma-mass spectrometry (ICP-MS).Keywords
Funding Information
- Universiti Kebangsaan Malaysia (GUP-2021-066)
This publication has 84 references indexed in Scilit:
- Managing Micronutrient Deficiencies in High-Risk Patients: No Small Feat!Current Nutrition Reports, 2024
- Effect of zinc intake on association between fluoride exposure and abnormal sex steroid hormones among US pubertal males: NHANES, 2013–2016Environmental Science and Pollution Research, 2023
- Ultraviolet photoelectron spectroscopy: Practical aspects and best practicesApplied Surface Science Advances, 2023
- A review on graphene and its derivatives as the forerunner of the two-dimensional material family for the futureJournal of Materials Science, 2022
- Quantum Chemistry‐based Molecular Dynamics Simulations as a Tool for the Assignment of ESI‐MS/MS Spectra of Drug MoleculesChemistry – A European Journal, 2022
- Electrofabrication of the Ternary NiCuFe Alloy Nanoparticles/ERGO Nanocomposite: Effective Electrooxidation of the Glucose and Glycerol in Alkaline MediaChemistrySelect, 2020
- Recent aspects of the effects of zinc on human healthArchives of Toxicology, 2020
- Rapid determination of trace elements in serum of hepatocellular carcinoma patients by inductively coupled plasma tandem mass spectrometryAnalytica Chimica Acta, 2020
- Improved anodic stripping voltammetric detection of zinc on a disposable screen-printed gold electrodeIonics, 2020
- Reduced graphene oxide-intercalated graphene oxide nano-hybrid for enhanced photoelectrochemical water reductionJournal of Nanostructure in Chemistry, 2019