The effect of calibration parameters on the control of a myoelectric hand prosthesis using EMG feedback
Open Access
- 22 June 2021
- journal article
- research article
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 18 (4) , 046091
Abstract
Objective. The implementation of somatosensory feedback in upper limb myoelectric prostheses is an important step towards the restoration of lost sensory-motor functions. EMG feedback is a recently proposed method for closing the control loop wherein the myoelectric signal that drives the prosthesis is also used to generate the feedback provided to the user. Therefore, the characteristics of the myoelectric signal (variability and sensitivity) are likely to significantly affect the ability of the subject to utilize this feedback for online control of the prosthesis. Approach. In the present study, we investigated how the cutoff frequency of the low-pass filter (0.5, 1 and 1.5 Hz) and normalization value (20%, 40% and 60% of the maximum voluntary contraction (MVC)), that are used for the generation of the myoelectric signal, affect the quality of closed-loop control with EMG feedback. Lower cutoff and normalization decrease the intrinsic variability of the EMG but also increase the time lag between the contraction and the feedback (cutoff) as well as the sensitivity of the myoelectric signal (normalization). Ten participants were asked to generate three grasp force levels with a myoelectric prosthetic hand, while receiving five-level vibrotactile EMG feedback, over nine experimental runs (all parameter combinations). Main results. The outcome measure was the success rate (SR) in achieving the appropriate level of myoelectric signal (primary outcome) and grasping force (secondary outcome). Overall, the experiments demonstrated that EMG feedback provided robust control across conditions. Nevertheless, the performance was significantly better for the lowest cutoff (0.5 Hz) and higher normalization (40% and 60%). The highest SR for the EMG was 71.9%, achieved in the condition (40% MVC and 0.5 Hz), and this was 24.1% higher than that in the condition (20% MVC and 1.5 Hz), which resulted in the lowest performance. The SR for the force followed a similar trend. Significance. This is the first study that systematically explored the parameter space for the calibration of EMG feedback, which is a critical step for the future clinical application of this approach.Keywords
Funding Information
- Teknologi og Produktion, Det Frie Forskningsråd (8022-00226B)
This publication has 39 references indexed in Scilit:
- Current rates of prosthetic usage in upper-limb amputees – have innovations had an impact on device acceptance?Disability and Rehabilitation, 2020
- Social participation in persons with upper limb amputation receiving an esthetic prosthesisJournal of Hand Therapy, 2020
- Upper limb amputation; Care needs for reintegration to life: An integrative reviewInternational Journal of Orthopaedic and Trauma Nursing, 2020
- Psychological effects of traumatic upper-limb amputationsOrthopaedics & Traumatology: Surgery & Research, 2020
- The clinical relevance of advanced artificial feedback in the control of a multi-functional myoelectric prosthesisJournal of NeuroEngineering and Rehabilitation, 2018
- Return to Work Following Major Limb Loss2016
- Forearm amputees' views of prosthesis use and sensory feedbackJournal of Hand Therapy, 2015
- Sensory feedback in upper limb prostheticsExpert Review of Medical Devices, 2013
- Myoelectric forearm prostheses: State of the art from a user-centered perspectiveJournal of Rehabilitation Research and Development, 2011
- Amputation rehabilitation and prosthetic restoration. From surgery to community reintegrationDisability and Rehabilitation, 2004