Improved techniques for rotor fault detection in three-phase induction motors
Authors:
- N.C. PatersonNPN.C. Paterson
- 27 November 2002
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 1 (01972618) , 271-277
Abstract
A technique has been developed whereby faults in 3 phase induction motors can be detected by an analysis of a single, no-load, starting transient. The system has been developed on laboratory test-rigs and validated via computer simulation and industrial testing. The basis of the technique is explained and simulation and test data presented. Possible areas of future application and development are discussed.Keywords
This publication has 3 references indexed in Scilit:
- An unsupervised, on-line system for induction motor fault detection using stator current monitoring2002
- The application of modern signal processing techniques for use in rotor fault detection and location within three-phase induction motorsSignal Processing, 1996
- Vibration and current monitoring for detecting airgap eccentricity in large induction motorsIEE Proceedings B Electric Power Applications, 1986