Graphene-Based Glucose Sensors with an Attomolar Limit of Detection
Top Cited Papers
- 3 April 2025
- journal article
- Published by American Chemical Society (ACS) in Journal of the American Chemical Society
- Vol. 147 (15) , 13059-13070
Abstract
Diabetes mellitus, a prevalent metabolic disorder affecting hundreds of millions of people worldwide, demands continuous glucose monitoring for effective management. Current blood glucose monitoring methods, such as commercial glucometers, are accurate but are often perceived as uncomfortable. Motivated by the need for noninvasive, ultrasensitive alternatives, our study presents electrolyte-gated graphene field-effect transistors functionalized with glucose oxidase. We developed an optimized fabrication process that integrates a 32-transistor matrix within a miniaturized 1000 μm2 footprint, ensuring high device uniformity while enabling detection in 40 μL analyte volume. A comprehensive suite of techniques─including Raman spectroscopy, X-ray photoelectron spectroscopy, and water contact angle measurements─reveals the stepwise evolution of graphene chemistry and surface properties leading to the controlled immobilization of glucose oxidase. Our findings demonstrate p-type doping and tensile strain in the graphene channel across the nanomolar-millimolar glucose concentration range. The enzyme-catalyzed oxidation of glucose produces hydrogen peroxide in close proximity to the graphene channel, inducing a systematic shift in the Dirac point voltage toward more positive values. Under these conditions, the biosensor achieves an attomolar limit of detection and a sensitivity of 10.6 mV/decade, outperforming previously reported glucose sensors. Selectivity tests against common interferents such as lactate and ascorbic acid, as well as validation in artificial and human tears, demonstrate its robustness for real-world applications. Altogether, these findings position the electrolyte-gated graphene field-effect transistor as a transformative, noninvasive glucose-sensing platform, paving the way for next-generation continuous monitoring devices, including wearable formats for real-time, user-friendly diabetes management.Keywords
All Related Versions
Funding Information
- Funda??o para a Ci?ncia e a Tecnologia (DRI/India/0664/2020)
This publication has 91 references indexed in Scilit:
- Glucose measurement via Raman spectroscopy of graphene: Principles and operationNano Research, 2022
- Grafting Ink for Direct Writing: Solvation Activated Covalent Functionalization of GrapheneAdvanced Science, 2022
- Diabetes Mellitus2020
- Enzyme‐Based Glucose Sensor: From Invasive to Wearable DeviceAdvanced Healthcare Materials, 2018
- Graphene Field‐Effect Transistors for the Sensitive and Selective Detection of Escherichia coli Using Pyrene‐Tagged DNA AptamerAdvanced Healthcare Materials, 2017
- Solution‐Gated Graphene Transistors for Chemical and Biological SensorsAdvanced Healthcare Materials, 2013
- Non-enzymatic electrochemical sensing of glucoseMicrochimica Acta, 2012
- Ultra-Sensitivity Glucose Sensor Based on Field EmittersDiscover Nano, 2009
- Doping Single‐Layer Graphene with Aromatic MoleculesSmall, 2009
- Chemically Modified Glucose Oxidase with Enhanced Hydrophobicity: Adsorption at Polystyrene, Silica, and Silica Coated by Lipid MonolayersJournal of Colloid and Interface Science, 1999