Mercury Sorption and Desorption on Gold: A Comparative Analysis of Surface Acoustic Wave and Quartz Crystal Microbalance-Based Sensors
Authors:
- K. M. Mohibul KabirKKK. M. Mohibul Kabir
- Ylias M. SabriYlias M. Sabri
- Ahmad Esmaielzadeh KandjaniAKAhmad Esmaielzadeh Kandjani
- Glenn I. MatthewsGMGlenn I. Matthews
- Matthew FieldMFMatthew Field
- Lathe A. JonesLathe A. Jones
- Ayman NafadyAyman Nafady
- Samuel J. IppolitoSISamuel J. Ippolito
- Suresh K BhargavaSBSuresh K Bhargava
- 13 July 2015
- journal article
- research article
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 31 (30) , 8519-8529
Abstract
Microelectromechanical sensors based on surface acoustic wave (SAW) and quartz crystal microbalance (QCM) transducers possess substantial potential as online elemental mercury (Hg0) vapor detectors in industrial stack effluents. In this study, a comparison of SAW- and QCM-based sensors is performed for the detection of low concentrations of Hg0 vapor (ranging from 24 to 365 ppbv). Experimental measurements and finite element method (FEM) simulations allow the comparison of these sensors with regard to their sensitivity, sorption and desorption characteristics, and response time following Hg0 vapor exposure at various operating temperatures ranging from 35 to 75 °C. Both of the sensors were fabricated on quartz substrates (ST and AT cut quartz for SAW and QCM devices, respectively) and employed thin gold (Au) layers as the electrodes. The SAW-based sensor exhibited up to ∼111 and ∼39 times higher response magnitudes than did the QCM-based sensor at 35 and 55 °C, respectively, when exposed to Hg0 vapor concentrations ranging from 24 to 365 ppbv. The Hg0 sorption and desorption calibration curves of both sensors were found to fit well with the Langmuir extension isotherm at different operating temperatures. Furthermore, the Hg0 sorption and desorption rate demonstrated by the SAW-based sensor was found to decrease as the operating temperature increased, while the opposite trend was observed for the QCM-based sensor. However, the SAW-based sensor reached the maximum Hg0 sorption rate faster than the QCM-based sensor regardless of operating temperature, whereas both sensors showed similar response times (t90) at various temperatures. Additionally, the sorption rate data was utilized in this study in order to obtain a faster response time from the sensor upon exposure to Hg0 vapor. Furthermore, comparative analysis of the developed sensors’ selectivity showed that the SAW-based sensor had a higher overall selectivity (90%) than did the QCM counterpart (84%) while Hg0 vapor was measured in the presence of ammonia (NH3), humidity, and a number of volatile organic compounds at the chosen operating temperature of 55 °C.Keywords
Funding Information
- King Saud University
- Australian Research Council (LP100200859)
This publication has 34 references indexed in Scilit:
- Gold nanospikes based microsensor as a highly accurate mercury emission monitoring systemScientific Reports, 2014
- Virtual Atmospheric Mercury Emission Network in ChinaEnvironmental Science & Technology, 2014
- Anthropogenic Mercury Flows in India and Impacts of Emission ControlsEnvironmental Science & Technology, 2013
- Tough talk over mercury treatyNature, 2013
- The toxicology of mercury and its compoundsJournal of Trace Elements in Medicine and Biology, 2012
- Is low-level environmental mercury exposure of concern to human health?Science of The Total Environment, 2009
- Sensing Mercury for Biomedical and Environmental MonitoringSensors, 2009
- Use of continuous mercury monitors at coal-fired utilitiesFuel Processing Technology, 2004
- Subnanogram determination of mercury by two-stage gold amalgamation and gas phase detection applied to atmospheric analysisAnalytical Chemistry, 1979
- Determination of submicrogram quantities of mercury by atomic absorption spectrophotometryAnalytical Chemistry, 1968