Abstract
This paper presents an approach to predict the thermal utilization of permanent magnet synchronous motors (PMSM), which geometrically varies, by employing scaling laws. Once a FE-simulation is performed for a reference machine analytical equations can be used to calculate magnetic quantities and losses of a machine with modified dimensions. These losses are used as an input for a scalable thermal model to determine the winding temperature of the machine. The thermal load is required to estimate the life time of the insulation system and the PMSM itself. The simplicity of the thermal model which is used here allows for short overall computing times. Both, radial and axial scaling are applied. In this paper downscaling is used to increase the thermal utilization of a PMSM.