Separation of electrocardiographic from electromyographic signals using dynamic filtration
- 24 April 2018
- journal article
- research article
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 57 (1) , 1-10
Abstract
Trunk muscle electromyographic (EMG) signals are often contaminated by the electrical activity of the heart. During low or moderate muscle force, these electrocardiographic (ECG) signals disturb the estimation of muscle activity. Butterworth high-pass filters with cut-off frequency of up to 60 Hz are often used to suppress the ECG signal. Such filters disturb the EMG signal in both frequency and time domain. A new method based on the dynamic application of Savitzky-Golay filter is proposed. EMG signals of three left trunk muscles and pure ECG signal were recorded during different motor tasks. The efficiency of the method was tested and verified both with the experimental EMG signals and with modeled signals obtained by summing the pure ECG signal with EMG signals at different levels of signal-to-noise ratio. The results were compared with those obtained by application of high-pass, 4th order Butterworth filter with cut-off frequency of 30 Hz. The suggested method is separating the EMG signal from the ECG signal without EMG signal distortion across its entire frequency range regardless of amplitudes. Butterworth filter suppresses the signals in the 0-30 Hz range thus preventing the low-frequency analysis of the EMG signal. An additional disadvantage is that it passes high-frequency ECG signal components which is apparent at equal and higher amplitudes of the ECG signal as compared to the EMG signal. The new method was also successfully verified with abnormal ECG signals.Keywords
Funding Information
- Bulgarian Academy of Sciences (ДФНП-17-132)
This publication has 13 references indexed in Scilit:
- Noise processing in exercise ECG stress test for the analysis and the clinical characterization of QRS and T wave alternansBiomedical Signal Processing and Control, 2015
- Removing ECG contamination from EMG recordings: A comparison of ICA-based and other filtering proceduresJournal of Electromyography and Kinesiology, 2012
- Relationship Between Firing Rate and Recruitment Threshold of Motoneurons in Voluntary Isometric ContractionsJournal of Neurophysiology, 2010
- A simple method to remove ECG artifacts from trunk muscle EMG signalsJournal of Electromyography and Kinesiology, 2009
- Removing ECG noise from surface EMG signals using adaptive filteringNeuroscience Letters, 2009
- Recommendations for the Standardization and Interpretation of the ElectrocardiogramJACC, 2007
- Elimination of electrocardiogram contamination from electromyogram signals: An evaluation of currently used removal techniquesJournal of Electromyography and Kinesiology, 2006
- Adaptive filtering for ECG rejection from surface EMG recordingsJournal of Electromyography and Kinesiology, 2005
- EMG and muscle force: An introductionHuman Movement Science, 1984
- Smoothing and Differentiation of Data by Simplified Least Squares Procedures.Analytical Chemistry, 1964