Quantification of aortic elasticity: development and experimental validation of a method using computed tomography
Authors:
- 26 July 2005
- journal article
- research article
- Published by Springer Nature in European Radiology
- Vol. 15 (12) , 2506-2512
Abstract
Aortic distensibility depending on aortic cross-sectional area changes is an important parameter for the grading of vascular diseases. This study measured aortic area changes by multidetector computed tomography. An image reconstruction algorithm was developed to assess aorta diameter and area as a function of the cardiac cycle with sufficient time resolution along the entire length of the aorta by four-detector row computed tomography. The algorithm was tested on porcine aortic specimens and compared with an optical reference method. The error of the relative vessel area change comparing the two methods was found to be about 3%. Initial tests on patient datasets indicate that clinical application is feasible. The proposed method has the advantage that it can easily be integrated into a modified routine CT angiography study and allows the measurement of aortic cross-sectional area changes.Keywords
This publication has 27 references indexed in Scilit:
- Aortic pressure–area relation in Marfan patients with and without β blocking agents: a new non-invasive approachHeart, 2004
- Arterial compliance adds to conventional risk factors for prediction of angiographic coronary artery diseaseAmerican Heart Journal, 2003
- Aortic Stiffness Is an Independent Predictor of Fatal Stroke in Essential HypertensionStroke, 2003
- Relationship of Peripheral Arterial Compliance and Standard Cardiovascular Risk FactorsVascular and Endovascular Surgery, 2003
- Dose Reduction in Multi-slice CT of the Heart by Use of ECG-controlled Tube Current Modulation (“ECG pulsing”): Phantom MeasurementsRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2002
- ECG‐correlated image reconstruction from subsecond multi‐slice spiral CT scans of the heartMedical Physics, 2000
- A velocity correlation method for measuring vascular compliance using MR imagingJournal of Magnetic Resonance Imaging, 1995
- Diameter and compliance in the human common carotid artery — variations with age and sexUltrasound in Medicine & Biology, 1995
- Automatic Enhancement, Animation, and Segmentation of Flow in Peripheral Arteries from MR Phase-Shift Velocity MappingJournal of Computer Assisted Tomography, 1992
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986