An in vitro study of the reliability of DIAGNOdent® measurements
Authors:
- 15 September 2004
- journal article
- research article
- Published by Wiley in Journal of Oral Rehabilitation
- Vol. 31 (9) , 895-899
Abstract
summary Aim of this in vitro study was to assess the reliability of measurements by a laser fluorescence technique for occlusal caries detection. Four dentists using four DIAGNOdent® devices (Dds) according to manufacturer's instructions examined 80 carefully cleaned extracted molars with non‐cavitated occlusal lesions. Inter‐ and intra‐examiner reproducibility were calculated using Lin's intra‐class correlation coefficient (ICCLin) and the limits of agreement by Bland and Altman (Comp Biol Med 1990;20:337). An excellent intra‐examiner reproducibility was found for all dentists (ICCLin 0·93–0·98). The inter‐examiner reliability was proved to be good and excellent (ICCLin 0·74–0·98). By reason of the registered lower mean fluorescence values of dentist 3 compared with his/her colleagues all these measurements were excluded from further calculations. Differences between Dd instruments were not evident. When the values of the Dd were categorized according to the treatment related cut‐off limits a substantial reproducibility was found in the range of 0–14 (ICCLin 0·66; DIFF 4·0/−3·5) and >30 (ICCLin 0·6% of all Dd measurements were reproduced in the range 15–30 (ICCLin 0·16; DIFF 8·1/−7·3). The results suggest that dentists should be trained before using Dd. The low reliability in the interval of 15‐30 could indicate a limited use for a longitudinal caries monitoring on pits and fissures; further research should be focused on this clinically important interval.Keywords
This publication has 7 references indexed in Scilit:
- Caries Detection Methods: Can They Aid Decision Making for Invasive Sealant Treatment?Caries Research, 2001
- Clinical performance of a laser fluorescence device for detection of occlusal caries lesionsEuropean Journal of Oral Sciences, 2001
- Occlusal Caries Detection with KaVo DIAGNOdent and Radiography: An in vitro ComparisonCaries Research, 2000
- New approach on fluorescence spectroscopy for caries detection1999
- Performance and Reproducibility of a Laser Fluorescence System for Detection of Occlusal Caries in vitroCaries Research, 1999
- A note on the use of the intraclass correlation coefficient in the evaluation of agreement between two methods of measurementComputers in Biology and Medicine, 1990
- A Concordance Correlation Coefficient to Evaluate Reproducibility1989