In vitro sliding‐driven morphological changes in representative esthetic NiTi archwire surfaces
Authors:
- 17 August 2015
- journal article
- research article
- Published by Wiley in Microscopy Research and Technique
- Vol. 78 (10) , 926-934
Abstract
Objectives: This study investigated the effects of sliding on the ultrastructure of three representative esthetic superelastic 0.014 inch nickel‐titanium (NiTi) archwires. Methods: Atomic force microscopy, scanning electron microscopy, and light microscopy were used to estimate the surface roughness of archwires and bracket systems. Energy‐dispersive X‐ray spectroscopy was used to estimate the molecular differences between coated and uncoated areas. A combination of four different types of 0.014 inch metallic wires and two different types of 0.022 inch × 0.028 inch conventional brackets were evaluated by in vitro sliding tests using a novel self‐made tensile‐strength tester with a miniature load cell and syringe pump. The NiTi wires included an uncoated NiTi archwire (CO group), epoxy resin‐coated NiTi archwire (ER group), Teflon®‐coated NiTi archwire (TF group), and Ag/biopolymer‐coated NiTi archwire (AG group). The brackets included contained stainless steel (SS) and ceramic (CE) brackets. Results: Both ER and TF wire groups exhibited less surface roughness than CO wire groups. The AG group showed the highest surface roughness compared with the others because of its silver particles (PP < 0.001, ANOVA test) in the surface roughness of all 0.014 inch NiTi wires regardless of bracket type. The wire groups combined with SS brackets were rougher than those of CE brackets regardless of the coating materials because of exfoliation of the coating materials. The TF‐SS group showed the highest increase (fivefold) in surface roughness compared to the others, while the ER groups showed the lowest increase (1.4‐fold) in surface roughness compared with the others (P < 0.001, ANOVA test). Conclusions: The results suggested that the sliding‐driven surface roughness of superelastic NiTi archwires is directly affected by coating materials. Although the efficiency of orthodontic treatment was affected by various factors, epoxy resin‐coated archwires were best for both esthetics and tooth movement when only considering surface roughness. Microsc. Res. Tech. 78:926–934, 2015.Keywords
Funding Information
- Ministry of Health & Welfare, Republic of Korea (Korean Health Technology Research & Development Project) (HI14C2241)
This publication has 20 references indexed in Scilit:
- Correlation between frictional force and surface roughness of orthodontic archwiresScanning, 2015
- Coating stability and surface characteristics of esthetic orthodontic coated archwiresThe Angle Orthodontist, 2013
- An investigation into the mechanical and aesthetic properties of new generation coated nickel-titanium wires in the as-received state and after clinical useEuropean Journal of Orthodontics, 2013
- Evaluation of surface roughness of orthodontic wires by means of atomic force microscopyThe Angle Orthodontist, 2012
- Ultrastructural effect of self‐ligating bracket materials on stainless steel and superelastic niTi wire surfacesMicroscopy Research and Technique, 2012
- Load-deflection and surface properties of coated and conventional superelastic orthodontic archwires in conventional and metal-insert ceramic bracketsDental Research Journal, 2012
- Effects of self‐ligating brackets on the surfaces of stainless steel wires following clinical use: AFM investigationJournal of Microscopy, 2011
- Changes in Ultrastructure and properties of bracket slots after Orthodontic treatment with bicuspid extractionScanning, 2011
- Static frictional force and surface roughness of various bracket and wire combinationsAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2011
- Friction of Conventional and Silica-Insert Ceramic Brackets in Various Bracket-Wire CombinationsThe Angle Orthodontist, 2007