Stopping-power ratio of body tissues with updated effective energies and elemental I values for treatment planning of proton therapy and ion beam therapy with helium, carbon, oxygen, and neon ions
Authors:
- 23 April 2023
- journal article
- research article
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 16 (2) , 319-324
Abstract
The stopping-power ratio (SPR) of body tissues relative to water depends on the particle energy and mean excitation energy (I value) of the tissues. Effective energies to minimize the range error in proton therapy and ion beam therapy with helium, carbon, oxygen, and neon ions and elemental I values have been updated in recent studies. We investigated the effects of these updates on SPR estimation for computed tomography-based treatment planning. The updates led to an increase of up to 0.5% in the SPRs of soft tissues, whereas they led to a decrease of up to 1.9% in the SPRs of bone tissues compared with the current clinical settings. For 44 proton beams planned for 15 randomly sampled patients, the mean water-equivalent target depth change was − 0.2 mm with a standard deviation of 0.2 mm. The maximum change was − 0.6 mm, which we consider to be insignificant in clinical practice.Keywords
Funding Information
- Japan Society for the Promotion of Science (20K08123, 20K08013)
- Exploratory Research for Advanced Technology (JPMJER20102)
This publication has 6 references indexed in Scilit:
- Treatment planning of intensity modulated composite particle therapy with dose and linear energy transfer optimizationPhysics in Medicine & Biology, 2017
- Effective particle energies for stopping power calculation in radiotherapy treatment planning with protons and helium, carbon, and oxygen ionsPhysics in Medicine & Biology, 2016
- Modeling of body tissues for Monte Carlo simulation of radiotherapy treatments planned with conventional x-ray CT systemsPhysics in Medicine & Biology, 2016
- Range uncertainties in proton therapy and the role of Monte Carlo simulationsPhysics in Medicine & Biology, 2012
- A CT calibration method based on the polybinary tissue model for radiotherapy treatment planningPhysics in Medicine & Biology, 2003
- The calibration of CT Hounsfield units for radiotherapy treatment planningPhysics in Medicine & Biology, 1996