A roadmap for implementation of kV-CBCT online adaptive radiation therapy and initial first year experiences
Authors:
- Dennis N. StanleyDSDennis N. Stanley
- Joseph HarmsJHJoseph Harms
- Joel A. PogueJPJoel A. Pogue
- Jean-Guy BelliveauJBJean-Guy Belliveau
- Samuel R. MarcromSMSamuel R. Marcrom
- Michael C. DobelbowerMDMichael C. Dobelbower
- Drexell H. BoggsDBDrexell H. Boggs
- Michael H. SoikeMSMichael H. Soike
- John A. FiveashJFJohn A. Fiveash
- Richard A. PoppleRPRichard A. Popple
- Carlos E. CardenasCCCarlos E. Cardenas
Preprint
Abstract
Purpose: Online Adaptive Radiation Therapy(oART) follows a different treatment paradigm than conventional radiotherapy and, because of this, the resources, implementation, and workflows needed are unique. The purpose of this report is to outline our institution’s experience establishing, organizing, and implementing an oART program using the Ethos therapy system. Methods: We include resources used; operational models utilized, program creation timelines, and our institutional experiences with implementation and operation of an oART program. Additionally, we provide a detailed summary of our first year’s clinical experience where we delivered over 1000 daily adaptive fractions. For all treatments, the different stages of online adaption, primary patient set-up, initial kV-CBCT acquisition, contouring review and edit of influencer structures, target review and edits, plan evaluation and selection, Mobius3D 2 nd check and adaptive QA, 2 nd kV-CBCT for positional verification, treatment delivery, and patient leaving the room, were analyzed. Results: We retrospectively analyzed data from ninety-seven patients treated from August 2021-August 2022. 1677 individual fractions were treated and analyzed, 632(38%) were non-adaptive and 1045(62%) were adaptive. 74 of the 97 patients (76%) were treated with standard fractionation and 23 (24%) received stereotactic treatments. For the adaptive treatments, the generated adaptive plan was selected in 92% of treatments. On average(±std), adaptive sessions took 34.52±11.42 minutes from start to finish. The entire adaptive process (from start of contour generation to verification CBCT), performed by the physicist (and physician on select days), was 19.84±8.21 minutes. Conclusion: We present our institution’s experience commissioning an oART program using the Ethos therapy system. It took us 12 months from project inception to treatment of our first patient and 12 months to treat 1000 adaptive fractions. Retrospective analysis of delivered fractions showed that average overall treatment time was approximately 35 minutes and average time for the adaptive component of treatment was approximately 20 minutes.Keywords
All Related Versions
- Published version: Journal of Applied Clinical Medical Physics, 24 (7), e13961.
This publication has 34 references indexed in Scilit:
- AAPM Medical Physics Practice Guideline 5.a.: Commissioning and QA of Treatment Planning Dose Calculations — Megavoltage Photon and Electron BeamsJournal of Applied Clinical Medical Physics, 2015
- Adaptive Radiotherapy for Head-and-Neck Cancer: Initial Clinical Outcomes From a Prospective TrialInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2012
- Validation of a new grid-based Boltzmann equation solver for dose calculation in radiotherapy with photon beamsPhysics in Medicine & Biology, 2010
- Role of Adaptive Radiotherapy During Concomitant Chemoradiotherapy for Lung Cancer: Analysis of Data From a Prospective Clinical TrialInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2009
- Task Group 142 report: Quality assurance of medical acceleratorsa)Medical Physics, 2009
- Phase II dose escalation study of image-guided adaptive radiotherapy for prostate cancer: Use of dose–volume constraints to achieve rectal isotoxicityInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2005
- AAPM's TG‐51 protocol for clinical reference dosimetry of high‐energy photon and electron beamsMedical Physics, 1999
- The use of adaptive radiation therapy to reduce setup error: a prospective clinical studyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1998
- A technique for the quantitative evaluation of dose distributionsMedical Physics, 1998
- Adaptive radiation therapyPhysics in Medicine & Biology, 1997