PURPOSE: To describe and quantify the errors inherent to topography-guided ablation of irregular corneas due to natural epithelial thickness compensatory remodeling. METHODS: Artemis very high-frequency (VHF) digital ultrasound scanning (ArcScan Inc) was performed on a cornea that had undergone radial keratotomy with inferior and superior trapezoidal keratotomies, resulting 27 years later in high irregular astigmatism (+6.50 −8.00 × 101) and severe loss of corrected distance visual acuity (CDVA) to 20/50. The epithelial thickness profile was highly irregular, masking a significant proportion of the true stromal irregularity from front corneal surface topography, which would have resulted in significant inaccuracies had a topography-guided ablation been performed. The stromal ablation pattern of a transepithelial phototherapeutic keratectomy (PTK) ablation was modeled, which appeared logically to reduce the areas of abnormal stromal surface elevation and resembled a hyperopic astigmatic ablation of approximately 3.50 diopters of cylinder. Artemis-assisted transepithelial PTK was performed to target the stromal irregularity masked by epithelium. RESULTS: Artemis-assisted transepithelial PTK induced a refractive change similar to that predicted (+2.24 −3.97 × 120), demonstrating the refractive shift produced by the epithelium. The epithelial thickness profile became relatively regular and CDVA returned to 20/20 −2 . Two topography wavefront-guided ablations were performed to correct the remaining topographic irregularity and refractive error, resulting in a near plano refraction, significantly lower higher order aberrations, and CDVA of 20/20 +2 . CONCLUSIONS: A knowledge of stromal surface shape and power shift produced by epithelial thickness profile alterations after corneal surgery has the potential of improving the efficacy and safety of custom corneal ablation.Keywords
This publication has 16 references indexed in Scilit:
- Change in Epithelial Thickness Profile 24 Hours and Longitudinally for 1 Year After Myopic LASIK: Three-dimensional Display With Artemis Very High-frequency Digital UltrasoundJournal of Refractive Surgery, 2012
- Transepithelial, Topography-guided Ablation in the Treatment of Visual Disturbances in LASIK Flap or Interface ComplicationsJournal of Refractive Surgery, 2012
- Epithelial Thickness Up to 26 Years After Radial Keratotomy: Three-dimensional Display With Artemis Very High-frequency Digital UltrasoundJournal of Refractive Surgery, 2011
- LASIK for Myopic Astigmatism and Presbyopia Using Non-Linear Aspheric Micro-Monovision with the Carl Zeiss Meditec MEL 80 PlatformJournal of Refractive Surgery, 2011
- Epithelial Thickness After Hyperopic LASIK: Three-Dimensional Display with Artemis Very High-Frequency Digital UltrasoundJournal of Refractive Surgery, 2010
- Accuracy and Reproducibility of Artemis Central Flap Thickness and Visual Outcomes of LASIK With the Carl Zeiss Meditec VisuMax Femtosecond Laser and MEL 80 Excimer Laser PlatformsJournal of Refractive Surgery, 2010
- Combined Artemis very high-frequency digital ultrasound-assisted transepithelial phototherapeutic keratectomy and wavefront-guided treatment following multiple corneal refractive proceduresJournal of Cataract & Refractive Surgery, 2006
- Very high-frequency ultrasound corneal analysis identifies anatomic correlates of optical complications of lamellar refractive surgeryOphthalmology, 1999
- Role of epithelial hyperplasia in regression following photorefractive keratectomy.British Journal of Ophthalmology, 1996
- Trapezoidal Astigmatic KeratotomyArchives of Ophthalmology (1950), 1986