Determination of transit dose profile for a 192Ir HDR source
Authors:
- R. A. RuboRRR. A. Rubo
- R. A. MinamisawaRMR. A. Minamisawa
- G. R. dos SantosGSG. R. dos Santos
- P. C. G. AntunesPAP. C. G. Antunes
- H. YoriyazHYH. Yoriyaz
- 30 April 2013
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 40 (5) , 051717
Abstract
Purpose:: Several studies have reported methodologies to calculate and correct the transit dose component of the moving radiation source for high dose rate (HDR) brachytherapy planning systems. However, most of these works employ the average source speed, which varies significantly with the measurement technique used, and does not represent a realistic speed profile, therefore, providing an inaccurate dose determination. In this work, the authors quantified the transit dose component of a HDR unit based on the measurement of the instantaneous source speed to produce more accurate dose values.Methods:: The Nucletron microSelectron‐HDR Ir‐192 source was characterized considering the Task Group 43 (TG‐43U1) specifications. The transit dose component was considered through the calculation of the dose distribution using a Monte Carlo particle transport code, MCNP5, for each source position and correcting it by the source speed. The instantaneous source speed measurements were performed in a previous work using two optical fibers connected to a photomultiplier and an oscilloscope. Calculated doses were validated by comparing relative dose profiles with those obtained experimentally using radiochromic films.Results:: TG‐43U1 source parameters were calculated to validate the Monte Carlo simulations. These agreed with the literature, with differences below 1% for the majority of the points. Calculated dose profiles without transit dose were also validated by comparison with ONCENTRA® Brachy v. 3.3 dose values, yielding differences within 1.5%. Dose profiles obtained with MCNP5 corrected using the instantaneous source speed profile showed differences near dwell positions of up to 800% in comparison to values corrected using the average source speed, but they are in good agreement with the experimental data, showing a maximum discrepancy of approximately 3% of the maximum dose. Near a dwell position the transit dose is about 22% of the dwell dose delivered by the source dwelling 1 s and reached 104.0 cGy per irradiation in a hypothetical clinical case studied in this work.Conclusions:: The present work demonstrated that the transit dose correction based on average source speed fails to accurately correct the dose, indicating that the correct speed profile should be considered. The impact on total dose due to the transit dose correction near the dwell positions is significant and should be considered more carefully in treatments with high dose rate, several catheters, multiple dwell positions, small dwell times, and several fractions.Keywords
Funding Information
- Fundação de Amparo à Pesquisa do Estado de São Paulo (2011/01913-4, 2011/23765-7, 2011/22778-8)
- Fundação de Amparo à Pesquisa do Estado de São Paulo (2011/01913-4, 2011/23765-7, 2011/22778-8)
This publication has 16 references indexed in Scilit:
- Report of the Task Group 186 on model‐based dose calculation methods in brachytherapy beyond the TG‐43 formalism: Current status and recommendations for clinical implementationMedical Physics, 2012
- Linearization of dose–response curve of the radiochromic film dosimetry systemMedical Physics, 2012
- Uncertainty analysis in MCNP5 calculations for brachytherapy treatmentApplied Radiation and Isotopes, 2011
- Direct measurement of instantaneous source speed for a HDR brachytherapy unit using an optical fiber based detectora)Medical Physics, 2010
- EGSnrc Monte Carlo calculated dosimetry parameters for and brachytherapy sourcesMedical Physics, 2008
- Evaluation of the water equivalence of solid phantoms using gamma ray transmission measurementsRadiation Measurements, 2008
- Ir-192 HDR transit dose and radial dose function determination using alanine/EPR dosimetryPhysics in Medicine & Biology, 2005
- Monte Carlo‐aided dosimetry of a new high dose‐rate brachytherapy sourceMedical Physics, 1998
- The transit dose component of high dose rate brachytherapy: direct measurements and clinical implicationsInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1993
- Dose determination in high dose-rate brachytherapyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1992