Accuracy of duplex ultrasonography versus angiotomography for the diagnosis of extracranial internal carotid stenosis
Authors:
- Raul Muffato DaolioRDRaul Muffato Daolio
- Luiz Fernando Santetti ZaninLZLuiz Fernando Santetti Zanin
- Carolina Dutra Queiroz FlumignanCFCarolina Dutra Queiroz Flumignan
- Nicolle CassolaNCNicolle Cassola
- Henrique Jorge Guedes NetoHNHenrique Jorge Guedes Neto
- José Eduardo Mourão SantosJSJosé Eduardo Mourão Santos
- Jorge Eduardo AmorimJAJorge Eduardo Amorim
- Luís Carlos Uta NakanoLNLuís Carlos Uta Nakano
- Ronald Luiz Gomes FlumignanRFRonald Luiz Gomes Flumignan
Open Access
- 1 January 2024
- journal article
- research article
- Published by FapUNIFESP (SciELO) in Revista do Colégio Brasileiro de Cirurgiões
- Vol. 51, e20243632
Abstract
Introduction: Internal carotid artery (ICA) stenosis causes about 15% of ischemic strokes. Duplex ultrasonography (DUS) is the first line of investigation of ICA stenosis, but its accuracy varies in the literature and it is usual to complement the study with another more accurate exam when faced with significant stenosis. There is a lack of studies that compare DUS with angiotomography (CTA) in the present literature. Methods: we performed an accuracy study, which compared DUS to CTA of patients in a tertiary hospital with a maximum interval of three months between tests. Patients were selected retrospectively, and two independent and certified vascular surgeons evaluated each image in a masked manner. When there was discordance, a third evaluator was summoned. We evaluated the diagnostic accuracy of ICA stenosis of 50-94% and 70-94%. Results: we included 45 patients and 84 arteries after inclusion and exclusion criteria applied. For the 50-94% stenosis range, DUS accuracy was 69%, sensitivity 89%, and specificity 63%. For the 70-94% stenosis range, DUS accuracy was 84%, sensitivity 61%, and specificity 93%. There was discordance between CTA evaluators with a change from clinical to surgical management in at least 37.5% of the conflicting reports. Conclusion: DUS had an accuracy of 69% for stenoses of 50-94% and 84% for stenoses of 70-94% of the ICA. The CTA analysis depended directly on the evaluator with a change in clinical conduct in more than 37% of cases.Keywords
This publication has 28 references indexed in Scilit:
- Editor's Choice – European Society for Vascular Surgery (ESVS) 2023 Clinical Practice Guidelines on the Management of Atherosclerotic Carotid and Vertebral Artery DiseaseEuropean Journal of Vascular and Endovascular Surgery, 2022
- PC126. Accuracy of Vascular Ultrasound Compared With Computed Tomography Angiography for Extracranial Carotid Stenosis ImagingJournal of Vascular Surgery, 2019
- Comparison of Measurement and Grading of Carotid Stenosis with Computed Tomography Angiography and Doppler UltrasoundAnnals of Vascular Surgery, 2018
- Carotid endarterectomy should not be based on consensus statement duplex velocity criteriaJournal of Vascular Surgery, 2017
- Multi-parametric ultrasound criteria for internal carotid artery disease—comparison with CT angiographyNeuroradiology, 2016
- Concordance rates of Doppler ultrasound and CT angiography in the grading of carotid artery stenosis: a systematic literature reviewJournal of Neurology, 2011
- 2011 ASA/ACCF/AHA/AANN/AANS/ACR/ASNR/CNS/SAIP/SCAI/SIR/SNIS/SVM/SVS Guideline on the Management of Patients With Extracranial Carotid and Vertebral Artery Disease: Executive summaryCatheterization and Cardiovascular Interventions, 2011
- The Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) statement: guidelines for reporting observational studiesJournal of Clinical Epidemiology, 2008
- Complications of cerebral angiography: a prospective analysis of 2,924 consecutive proceduresNeuroradiology, 2007
- Endarterectomy for Asymptomatic Carotid Artery StenosisJAMA, 1995