Evaporation of Electrolyte during SVET Measurements: The Scale of the Problem and the Solutions
Open Access
- 22 August 2019
- journal article
- research article
- Published by Wiley in Electroanalysis
- Vol. 31 (11) , 2290-2298
Abstract
The objective of this work is to investigate the scale of the effect of spontaneous solution evaporation during SVET (Scanning Vibrating Electrode Technique) measurements and demonstrate how it biases the final results. When SVET maps are continuously acquired for more than several hours, the measured currents are smaller than expected. This is attributed to solvent (typically water) evaporation which leads to an increase in solution conductivity over time. If this is not considered when converting the measured potential differences into the local current densities, the SVET results display currents smaller than the true ones. Here, this effect is studied with a platinum disk electrode as source of a constant current and a model corroding system consisting of the AA2024/CFRP galvanic couple. Corrective actions are proposed to mitigate the problem, either in the experimental set‐up or as numerical correction.Keywords
Funding Information
- Horizon 2020 Framework Programme (645676)
This publication has 38 references indexed in Scilit:
- Effect of probe tip inclination on the response of the Scanning Vibrating Electrode Technique to an idealised pit-like featureElectrochimica Acta, 2012
- Scanning Electrode Techniques for Investigating Near-Surface Solution Current Densities2005
- Localized Corrosion Currents and pH Profile over B[sub 4]C, SiC, and Al[sub 2]O[sub 3] Reinforced 6092 Aluminum CompositesJournal of the Electrochemical Society, 2005
- Quantitative Assessment of Localized Corrosion Occurring on Galvanized Steel Samples Using the Scanning Vibrating Electrode TechniqueCorrosion, 2004
- Artifacts Induced by Large-Amplitude Probe Vibrations in Localized Corrosion Measured by SVETJournal of the Electrochemical Society, 2003
- Localized Electrochemical Methods Applied to Cut Edge CorrosionJournal of the Electrochemical Society, 2000
- Limitations of In Situ Current Density Mapping for Vibrating Electrodes Close to Metal SurfacesCorrosion, 1990
- The Use of the Scanning Vibrating Electrode Technique for Detecting Defects in Ion Vapor-Deposited Aluminum on SteelCorrosion, 1987
- Current and Potential Transients during Localized Corrosion of Stainless SteelJournal of the Electrochemical Society, 1985
- The Effect of Humidity Upon the Rate of EvaporationEcology, 1933