Pollutant Recognition Based on Supervised Machine Learning for Indoor Air Quality Monitoring Systems
Open Access
- 11 August 2017
- journal article
- research article
- Published by MDPI AG in Applied Sciences
- Vol. 7 (8) , 823
Abstract
Indoor air may be polluted by various types of pollutants which may come from cleaning products, construction activities, perfumes, cigarette smoke, water-damaged building materials and outdoor pollutants. Although these gases are usually safe for humans, they could be hazardous if their amount exceeded certain limits of exposure for human health. A sophisticated indoor air quality (IAQ) monitoring system which could classify the specific type of pollutants is very helpful. This study proposes an enhanced indoor air quality monitoring system (IAQMS) which could recognize the pollutants by utilizing supervised machine learning algorithms: multilayer perceptron (MLP), K-nearest neighbour (KNN) and linear discrimination analysis (LDA). Five sources of indoor air pollutants have been tested: ambient air, combustion activity, presence of chemicals, presence of fragrances and presence of food and beverages. The results showed that the three algorithms successfully classify the five sources of indoor air pollution (IAP) with a classification rate of up to 100 percent. An MLP classifier with a model structure of 9-3-5 has been chosen to be embedded into the IAQMS. The system has also been tested with all sources of IAP presented together. The result shows that the system is able to classify when single and two mixed sources are presented together. However, when more than two sources of IAP are presented at the same period, the system will classify the sources as ‘unknown’, because the system cannot recognize the input of the new pattern.Keywords
This publication has 33 references indexed in Scilit:
- Quantifying the impact of traffic-related air pollution on the indoor air quality of a naturally ventilated buildingEnvironment International, 2016
- Electronic Noses for Environmental Monitoring ApplicationsSensors, 2014
- Development of an Electronic Nose for Environmental Odour MonitoringSensors, 2012
- Studies on the indoor air quality of Pharmaceutical Laboratories in MalaysiaInternational Journal of Sustainable Built Environment, 2012
- Smart Sensors Network for Air Quality Monitoring ApplicationsIEEE Transactions on Instrumentation and Measurement, 2009
- Identifying major contributing sources to odour annoyance using a non-specific gas sensor arrayBiosystems Engineering, 2009
- Odor Recognition for Intelligent SystemsIEEE Intelligent Systems, 2008
- Continuous monitoring of odours from a composting plant using electronic nosesWaste Management, 2007
- Environmental Comfort Criteria: Weighting and IntegrationJournal of Performance of Constructed Facilities, 2001
- Using the classification model of an electronic nose to assign unknown malodours to environmental sources and to monitor them continuouslySensors and Actuators B: Chemical, 2000