Correcting Laser-Based Water Stable Isotope Readings Biased by Carrier Gas Changes
- 22 June 2016
- journal article
- research article
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 50 (13) , 7074-7081
Abstract
Recently, laser-based water stable isotope spectrometers have become popular as they enable previously impossible approaches of environmental observations. Consequently, they have been subjected to increasingly heterogeneous atmospheric conditions. However, there is still a severe lack of data on the impact of nonstandardized gas matrices on analyzer performances. Against this background, we investigated the influence of changing proportions of N2, O2, and CO2 in the carrier gas on the isotope measurements of a typical laser-based water stable isotope analyzer (Picarro L2120-i). We combined environmentally relevant mixtures of N2, O2, and CO2 with referenced, flash-evaporated water and found that isotope readings of the same water were altered by up to +14.57‰ for δ18O and −35.9‰ for δ2H. All tested relationships between carrier gas changes and respective isotope readings were strongly linearly correlated (R2 > 0.99). Furthermore, an analyzer-measured variable allowed for reliable postcorrection of the biased isotope readings, which we additionally tested on field data. Our findings are of importance for environmental data obtained by analyzers based on the same technology. They are relevant for assays where inconsistent gas matrices or a mismatch in this regard between unknown and reference analyses cannot be excluded, which is in particular common when investigating the soil–vegetation–atmosphere continuum.Keywords
Funding Information
- Helmholtz Association
- Land Baden-Württemberg (7533-10-5-109)
This publication has 28 references indexed in Scilit:
- Determining the stable isotope composition of pore water from saturated and unsaturated zone core: improvements to the direct vapour equilibration laser spectrometry methodHydrology and Earth System Sciences, 2015
- Long-term and high-frequency non-destructive monitoring of water stable isotope profiles in an evaporating soil columnHydrology and Earth System Sciences, 2015
- Established methods and new opportunities for pore water stable isotope analysisHydrological Processes, 2015
- Monitoring water stable isotopic composition in soils using gas-permeable tubing and infrared laser absorption spectroscopyWater Resources Research, 2013
- Continuous in situ measurements of stable isotopes in liquid waterWater Resources Research, 2012
- Continuous analysis of δ 18 O and δD values of water by diffusion sampling cavity ring‐down spectrometry: a novel sampling device for unattended field monitoring of precipitation, ground and surface watersRapid Communications in Mass Spectrometry, 2011
- Realtime Stable Isotope Monitoring of Natural Waters by Parallel-Flow Laser SpectroscopyAnalytical Chemistry, 2011
- Demonstration of high‐precision continuous measurements of water vapor isotopologues in laboratory and remote field deployments using wavelength‐scanned cavity ring‐down spectroscopy (WS‐CRDS) technologyRapid Communications in Mass Spectrometry, 2009
- High Resolution Pore Water δ2H and δ18O Measurements by H2O(liquid)−H2O(vapor) Equilibration Laser SpectroscopyEnvironmental Science & Technology, 2008
- Sensitive absorption measurements in the near-infrared region using off-axis integrated-cavity-output spectroscopyApplied Physics B, 2002