Custom rotating-hinge total knee replacement in patients with spina bifida and severe neuromuscular dysfunction
- 21 June 2012
- journal article
- case report
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 132 (9) , 1321-1325
Abstract
Spina bifida (SB) is a congenital disorder which may result in a number of musculoskeletal problems. Total knee replacement (TKR) in this patient group is technically demanding due to bone deformity, soft tissue contracture, muscle tone abnormality and ligament insufficiency. This is a retrospective review of three patients with SB and disabling knee arthritis who were managed with a custom rotating-hinge (RHK) total knee system. All patients reported an improvement in knee pain and stability at mean follow-up 47 months (43–53). Mean Oxford Knee score improved from 21 preoperatively to 32 at final follow-up. One patient required revision of tibial and patella components at 37 months for lateral patella instability and excessive wear. Custom RHK for patients with SB, severe neuromuscular dysfunction and bone deformity relieves pain, restores stability and improves early knee function; however there is a significant risk of extensor mechanism complications and functional outcome is worse than primary TKR in the general population.Keywords
This publication has 7 references indexed in Scilit:
- Prevalence of Spina Bifida Among Children and Adolescents in 10 Regions in the United StatesPediatrics, 2010
- Total knee arthroplasty in patients with poliomyelitisThe Knee, 2009
- The SMILES prosthesis in salvage revision knee surgeryThe Knee, 2008
- Rotating Hinged Total Knee ReplacementJournal of Bone and Joint Surgery, 2007
- TOTAL KNEE ARTHROPLASTY IN PATIENTS WITH DIASTROPHIC DYSPLASIAJournal of Bone and Joint Surgery, 2003
- Total Knee Arthroplasty in Limbs Affected by PoliomyelitisJournal of Bone and Joint Surgery, 2002
- The Kinemax total knee arthroplastyThe Journal of Bone and Joint Surgery. British volume, 2001