Effect of Different Chemical Disinfectants on Color Stability of Acrylic Denture Teeth
- 13 January 2014
- journal article
- research article
- Published by Wiley in Journal of Prosthodontics
- Vol. 23 (6) , 476-483
Abstract
Purpose: The purpose of this study was to evaluate the effects of chemical disinfectants on the color stability of acrylic denture teeth (ADT) via spectrophotometric analysis.Materials and Methods: A total of 120 central ADT specimens were randomly assigned to eight experimental groups and immersed in the following solutions (n = 15). Tap water/control group (CON), neutral soap (NTS), 2% sodium hypochlorite (SHC1), 5.25% sodium hypochlorite (SHC2), sodium perborate (SPB), povidone‐iodine (PVI), chlorhexidine gluconate (CHG), and glutaraldehyde (GTA). Color measurements of teeth were performed by spectrophotometry after 10, 30, 48, 72, 144, and 960 immersion cycles in each tested solution. Color differences (ΔE*) were then evaluated using the Commission Internationale D'Eclairage (CIE) L*a* b* color system. Furthermore, Kruskal‐Wallis, Mann‐Whitney U, and Friedman comparison tests (α = 0.05) were performed on all data.Results: There were significant differences in ΔE* values (p < 0.05) among the eight experimental groups. In addition, the highest ∆E* values were obtained in group SHC2, followed, respectively, by the SHC1, CHG, SPB, PVI, NTS, and CON groups.Conclusion: All the chemical disinfectants used in the study affected the color values of ADTs. Furthermore, ΔE* values increased along with the number of immersion cycles and total immersion time.Keywords
This publication has 43 references indexed in Scilit:
- Effect of Disinfection Treatments on the Hardness of Soft Denture Liner MaterialsJournal of Prosthodontics, 2007
- Hardness of heat-polymerized acrylic resins after disinfection and long-term water immersionThe Journal of Prosthetic Dentistry, 2005
- A between-patient disinfection method to control water line contamination and biofilm inside dental unitsJournal of Hospital Infection, 2004
- Evaluation of gloss changes of two denture acrylic resin materials in four different beveragesDental Materials, 2004
- Accuracy of polyether and addition silicone after long-term immersion disinfectionThe Journal of Prosthetic Dentistry, 1997
- Effects of chemical disinfectants on the surface characteristics and color of denture resinsThe Journal of Prosthetic Dentistry, 1997
- Aerobic bacterial contamination in dental materialsOral Surgery, Oral Medicine, Oral Pathology, 1990
- The recovery and significance of nonoral opportunistic pathogenic bacteria in dental laboratory pumiceThe Journal of Prosthetic Dentistry, 1985
- Gypsum casts as a potential source of microbial cross-contaminationThe Journal of Prosthetic Dentistry, 1983
- The microbiologic cross-contamination of dental prosthesesThe Journal of Prosthetic Dentistry, 1982