A Novel Total Cervical Prosthesis for Single-Level Cervical Subtotal Corpectomy
- 1 April 2015
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Spinal Disorders & Techniques
- Vol. 28 (3) , E166-E172
Abstract
Study Design: A novel total cervical prosthesis (TCP) for single-level cervical subtotal corpectomy was assessed in a caprine animal model. Objectives: To investigate the radiologic and histomorphometric characteristics of a novel TCP for single-level cervical subtotal corpectomy. Summary of Background: Cervical disk replacement has emerged as a promising alternative to arthrodesis in the management of cervical disk herniation. However, they are designed for anterior cervical discectomy, and not suitable for cervical subtotal corpectomy. To solve this problem, our group has developed a novel TCP for single-level cervical subtotal corpectomy. Materials and Methods: There were 12 adult Shannxi goats (2 y old) used in this study. The goats were divided into 2 groups based on postoperative survival periods of 3 (n=6) and 6 (n=6) months after surgery. Using an anterior surgical approach, a standard anterior C3 vertebra subtotal corpectomy and decompression of the spinal canal were performed, followed by implantation of the TCP device. Then all the goats were killed and underwent radiographic and histologic observations. Results: The TCP implant procedures were successfully completed in all 12 goats without incidence of vascular or infectious complications. The range of motion of C2–C3 and C3–C4 segments were preserved in both of the groups. Three-dimensional images of specimens interface indicated confluent interdigitization of trabeculae at the prosthetic endplate-bone interface, without evidence of significant radiolucent lines or gaps. Histomorphometric analysis showed that there were a large number of fibrous tissue and a small amount of cartilage cells between the prostheses and bone in the 3 months’ group. In the 6 months’ group, part of fibrous tissue has changed into the cartilage tissue. Conclusions: Our data show that this prosthesis can maintain the stability of the cervical spine and retain the activity of the cervical spine in vivo. The findings in this study provide a foundation for ongoing clinical investigations using the TCP.Keywords
This publication has 18 references indexed in Scilit:
- Artificial Cervical Vertebra and Intervertebral Complex Replacement through the Anterior Approach in Animal Model: A Biomechanical and In Vivo Evaluation of a Successful Goat ModelPLOS ONE, 2012
- Biomechanical Evaluation of a Novel Total Cervical Prosthesis in a Single-Level Cervical Subtotal Corpectomy Model: An In Vitro Human Cadaveric StudyJournal of Surgical Research, 2012
- Posterior Facet Load Changes in Adjacent Segments due to Moderate and Severe Degeneration in C5-C6 DiscJournal of Spinal Disorders & Techniques, 2012
- A prospective clinical and radiological study comparing hydroxyapatite-coated with cemented tibial components in total knee replacementThe Journal of Bone and Joint Surgery. British volume, 2012
- The Addition of a Hydroxyapatite Coating Changes the Immediate Postoperative Stability of a Plasma-Sprayed Femoral StemThe Journal of Arthroplasty, 2011
- Assessment of adjacent-segment mobility after cervical disc replacement versus fusion: RCT with 1 year’s resultsEuropean Spine Journal, 2011
- Long-Term Results of a Contemporary Metal-on-Metal Total Hip ArthroplastyThe Journal of Arthroplasty, 2010
- A clinical analysis of 4- and 6-year follow-up results after cervical disc replacement surgery using the Bryan Cervical Disc ProsthesisJournal of Neurosurgery: Spine, 2010
- Hydroxyapatite-coating of pedicle screws improves resistance against pull-out force in the osteoporotic canine lumbar spine model: a pilot studyThe Spine Journal, 2005
- Artificial cervical disc replacement: Principles, types and techniquesNeurology India, 2005