Segmentation of irregular porous particles of various sizes from X-ray microfocus computer tomography images using a novel adaptive watershed approach
Authors:
- 1 December 2015
- journal article
- Published by Emerald Publishing in Géotechnique Letters
- Vol. 5 (4) , 299-305
Abstract
This paper presents a novel adaptive watershed algorithm for the segmentation of soil particles in X-ray three-dimensional microfocus computer tomography images. An erosion-filling-dilation technique is also proposed, which is particularly suitable for processing images of highly porous particles. An s-factor is introduced to improve segmentation quality. In the inverse Euclidean distance map of the binary image, the topography in the zone around the local minima defined by this factor is modified. By using an appropriate value of s, the catchment basins and thus the watershed lines can be more realistically defined and it therefore resolves the problem of ill-segmentation. The proposed methods are applied to assemblages composed of highly porous particles with various size distributions, from uniformly graded to well graded or gap graded. The value of s can be decided based on visual examination of the segmentation quality on a sub-volume of the entire scanned domain. It is found that an s-factor that ranged from 0·5 to 0·7 is applicable to all of the studied cases, which enables a balance between under- and over-segmentation. Particulate-scale information including particle size distribution and particle shape characteristics is evaluated from the processed images and the results are compared with other available methods in the literature. Promising results are obtained.Keywords
This publication has 22 references indexed in Scilit:
- Microstructural analysis of sands with varying degrees of internal stabilityGéotechnique, 2014
- Exploring Image Binarization Techniques2014
- Full 3D investigation and characterisation of capillary collapse of a loose unsaturated sand using X-ray CTGranular Matter, 2013
- Experimental micro-mechanics of granular media studied by x-ray tomography: recent results and challengesGéotechnique Letters, 2013
- Micromechanisms of inelastic deformation in sandstones: an insight using x-ray micro-tomographyGéotechnique Letters, 2013
- X-ray microtomography characterisation of the changes in statistical homogeneity of an unsaturated sand during imbibitionGéotechnique Letters, 2013
- Non-invasive characterization of particle morphology of natural sandsSoils and Foundations, 2012
- Grain-scale experimental investigation of localised deformation in sand: a discrete particle tracking approachActa Geotechnica, 2011
- Spatial variation of void ratio and shear band thickness in sand using X-ray computed tomographyGéotechnique, 2008
- Distribution of local void ratio in porous media systems from 3D X-ray microtomography imagesPhysica A: Statistical Mechanics and its Applications, 2006