Case Report: Mislabeling of an online “alprazolam triazolobenzophenone” pill leads to severe intoxication with the novel synthetic opioid cychlorphine
Open Access
- 21 October 2026
- journal article
- case report
- Published by Frontiers Media SA in Frontiers in Toxicology
- Vol. 8, 1951240
Abstract
Background: Mislabeling of illicit drug products poses a serious risk to public health, especially in the rapidly evolving market for new psychoactive substances (NPS). Products sold as benzodiazepines may contain undisclosed novel synthetic opioids (NSOs), exposing opioid-naïve users to life-threatening respiratory depression. Case Report: A 34-year-old man ingested a pink tablet purchased online and labeled as “alprazolam triazolobenzophenone”, a ring-opened alprazolam prodrug, also known as “alprazafone”. Approximately 45 min after ingestion, he developed snoring and gasping respiration, hypoxemia and deep coma (Glasgow Coma Scale 3). Prehospital bag-valve ventilation and subsequent intubation resulted in prompt stabilization. The patient could be extubated 6 hours later. Contrary to the labeling, neither alprazolam nor its prodrug was detected in the tablet, blood or urine. Instead, the tablet contained approximately 1 mg of N -propionitrile chlorphine (cychlorphine), a piperidine benzimidazolone opioid of the emerging “orphine” class. Routine immunoassay screening for opioids and benzodiazepines was negative; identification required targeted LC-MS/MS. Six hours after ingestion, cychlorphine concentrations were 0.46 ng/mL in blood and 5.0 ng/mL in urine-to our knowledge the first human concentrations reported for this substance. In vitro , cychlorphine activated the µ-opioid receptor with an EC 50 of 2.7 nM, i.e. 4.5-fold more potent than fentanyl (EC 50 = 12.2 nM) within the same assay, with a binding affinity of K i = 1.09 nM (fentanyl: K i = 1.91 nM). The nitazene protonitazepyne was additionally detected in urine but not in blood or serum, indicating earlier intake and terminal elimination at the time of the event. Conclusion: This case documents cychlorphine as a highly potent NSO capable of causing life-threatening respiratory depression at sub-nanogram-per-millilitre blood concentrations, and illustrates the specific danger of benzodiazepine products adulterated with opioids. No pharmacokinetic data are available for cychlorphine. The concentration, measured 6 hours post-intake, therefore likely underestimates peak exposure. Clinicians should consider NSO exposure in unexplained respiratory depression after NPS use, even where a benzodiazepine was expected. Accessible drug-checking services, take-home naloxone and NSO-capable confirmatory analysis are needed.Keywords
This publication has 42 references indexed in Scilit:
- A Novel Workflow for Fast Elucidation of Drug Metabolites for Screening—Combining In Silico Metabolite Prediction With Trapped Ion Mobility QTOF‐MSDrug Testing and Analysis, 2026
- Pharmacology, prevalence in Germany, and analytical data of cyclobutylmethyl‐ and norbornylmethyl‐type synthetic cannabinoid receptor agonistsDrug Testing and Analysis, 2023
- Detection of AP‐237 and synthetic cannabinoids on an infused letter sent to a German prisonerDrug Testing and Analysis, 2022
- Pharmacological evaluation and forensic case series of N-pyrrolidino etonitazene (etonitazepyne), a newly emerging 2-benzylbenzimidazole ‘nitazene’ synthetic opioidArchives of Toxicology, 2022
- Mechanisms of opioid-induced respiratory depressionArchives of Toxicology, 2022
- Adulteration of low‐delta‐9‐tetrahydrocannabinol products with synthetic cannabinoids: Results from drug checking servicesDrug Testing and Analysis, 2022
- Application of a chiral high‐performance liquid chromatography‐tandem mass spectrometry method for the determination of 13 related amphetamine‐type stimulants to forensic samples: Interpretative hypothesesDrug Testing and Analysis, 2020
- Intoxication cases associated with the novel designer drug 3′,4′‐methylenedioxy‐α‐pyrrolidinohexanophenone and studies on its human metabolism using high‐resolution mass spectrometryDrug Testing and Analysis, 2020
- Mixed intoxication by the synthetic opioid U‐47700 and the benzodiazepine flubromazepam with lethal outcome: Pharmacokinetic dataDrug Testing and Analysis, 2018
- Evaluation of KIMS immunoassays on a cobas c 501 analyzer for drugs of abuse and ethyl glucuronide testing in urine for forensic abstinence controlDrug Testing and Analysis, 2017