Optical pumping enhancement of a free-induction-decay magnetometer
Authors:
- Dominic HunterDHDominic Hunter
- Marcin S. MrozowskiMMMarcin S. Mrozowski
- Allan McWilliamAMAllan McWilliam
- Stuart J. InglebySIStuart J. Ingleby
- Terry E. DyerTDTerry E. Dyer
- Paul F. GriffinPGPaul F. Griffin
- Erling RiisERErling Riis
Open Access
- 27 September 2023
- journal article
- research article
- Published by Optica Publishing Group in Journal of the Optical Society of America B
- Vol. 40 (10) , 2664-2673
Abstract
Spin preparation prior to a free-induction-decay (FID) measurement can be adversely affected by transverse bias fields, particularly in the geophysical field range. A strategy that enhances the spin polarization accumulated before readout is demonstrated, by synchronizing optical pumping with a magnetic field pulse that supersedes any transverse fields by over two orders of magnitude. The pulsed magnetic field is generated along the optical pumping axis using a compact electromagnetic coil pair encompassing a micro-electromechanical systems (MEMS) vapor cell. The coils also resistively heat the cesium vapor to the optimal atomic density without spurious magnetic field contributions as they are rapidly demagnetized to approximately zero field during spin readout. The demagnetization process is analyzed electronically, and directly with a FID measurement, to confirm that the residual magnetic field is minimal during detection. The sensitivity performance of this technique is compared to existing optical pumping modalities across a wide magnetic field range. A noise floor sensitivity of 238fT/Hz was achieved in a field of approximately 50 µT, in close agreement with the Cramér–Rao lower bound predicted noise density of 258fT/Hz.Keywords
All Related Versions
Funding Information
- Innovate UK (ISCF-42186)
This publication has 42 references indexed in Scilit:
- Measurement of longitudinal and transverse spin relaxation rates using the ground-state Hanle effectPhysical Review A, 2011
- Light-narrowed optically pumpedmagnetometer with a miniaturized Cs cellPhysical Review A, 2011
- Ultra-sensitive magnetometry based on free precession of nuclear spinsThe European Physical Journal D, 2010
- Spin-exchange relaxation-free magnetometry using elliptically polarized lightPhysical Review A, 2009
- A subfemtotesla multichannel atomic magnetometerNature, 2003
- High-Sensitivity Atomic Magnetometer Unaffected by Spin-Exchange RelaxationPhysical Review Letters, 2002
- Light narrowing of rubidium magnetic-resonance lines in high-pressure optical-pumping cellsPhysical Review A, 1999
- Cramer-Rao lower bounds for a damped sinusoidal processIEEE Transactions on Signal Processing, 1995
- Diverses résonances de croisement de niveaux sur des atomes pompés optiquement en champ nul II. Applications à la mesure de champs faiblesRevue de Physique Appliquée, 1970
- Avalanche Breakdown in SiliconPhysical Review B, 1954