Outcome of penile prosthesis implantation for treating erectile dysfunction: experience with 504 procedures
Open Access
- 6 December 2005
- journal article
- research article
- Published by Wiley in BJU International
- Vol. 97 (1) , 129-133
Abstract
OBJECTIVE: To evaluate the outcome of penile prosthesis surgery for different types of prosthesis. PATIENTS AND METHODS: The notes of 447 men who had 504 penile prosthesis implanted between August 1975 and December 2000 were evaluated. Of the prostheses inserted, 393 were malleable, 81 were three‐piece inflatable and 30 were self‐contained hydraulic prostheses. The mean (range) age of the men was 52 (21–78) years; 404 men had primary implants and 43 had revision surgery after operations at other institutions. The mean follow‐up was 50 (1–297) months. RESULTS: Of the 447 men, 22 were lost to follow‐up immediately after surgery. The most serious postoperative complications were infection (8%) and erosion (5%), which was more common in diabetic patients (10%) and after pelvic trauma with a urethral injury (21%). Of 482 prostheses, 21 failed mechanically (4%) and revision surgery was needed for 5% of the prostheses inserted (24/482). Overall, 89% (377/425) of men could have sexual intercourse and 344 (81%) were satisfied with the results. CONCLUSIONS: Of the men implanted with a penile prosthesis, 81% were satisfied with the outcome and an even higher proportion were satisfied with the inflatable prostheses. Dissatisfaction was mainly due to complications that resulted in removal of the prosthesis.Keywords
This publication has 27 references indexed in Scilit:
- EFFICACY, SAFETY AND PATIENT SATISFACTION OUTCOMES OF THE AMS 700CX INFLATABLE PENILE PROSTHESIS: RESULTS OF A LONG-TERM MULTICENTER STUDYJournal of Urology, 2000
- 10 YEARS OF EXPERIENCE WITH PENILE PROSTHESIS IMPLANTATION IN TAIWANESE PATIENTSJournal of Urology, 2000
- 10 YEARS OF EXPERIENCE WITH PENILE PROSTHESIS IMPLANTATION IN TAIWANESE PATIENTSJournal of Urology, 2000
- AMS Three–Piece Inflatable Implants for Erectile Dysfunction: A Long–Term Multi–Institutional Study in 200 Consecutive PatientsEuropean Urology, 2000
- QUANTIFYING RISK OF PENILE PROSTHESIS INFECTION WITH ELEVATED GLYCOSYLATED HEMOGLOBINJournal of Urology, 1998
- Safety and Efficacy Outcome of Mentor Alpha-1 Inflatable Penile Prosthesis Implantation for Impotence TreatmentJournal of Urology, 1997
- Inflatable penile prosthesis: results of 150 casesBritish Journal of Urology, 1996
- Long-term Results with Hydroflex and Dynaflex Penile ProsthesesJournal of Urology, 1996
- Inflatable Penile Implant InfectionJournal of Urology, 1995
- Penile prostheses for the management of the neuropathic bladder and sexual dysfunction in spinal cord injury patients: long term follow upSpinal Cord, 1994