Dose Distribution from kV-Cone Beam Computed Tomography in Image-guided Radiotherapy
Authors:
Open Access
- 1 January 2013
- journal article
- abstracts
- Published by Japanese Society of Radiological Technology in Japanese Journal of Radiological Technology
- Vol. 69 (7) , 753-760
Abstract
Image-guided radiotherapy (IGRT) is an increasingly commonly adopted technique. As a result, however, total patient dose is increasing rapidly, especially when kV-cone beam computed tomography (CBCT) is applied. This study investigated the dosimetry of kV-CBCT using a Farmer ionization chamber with a 60Co absorbed-dose calibration factor. The absorbed-dose measurements were performed using an I’mRT phantom (RW3, IBA) which is employed for dose verification of intensity-modulated radiotherapy (IMRT). The I’mRT phantom was used as a substitute for head and pelvis phantoms. The kV-CBCT absorbed dose was evaluated from a beam quality conversion factor of kV to 60Co and the ionization ratio of the I’mRT phantom and water, calculated using the Monte Carlo method. The dose distribution in the I’mRT phantom was also measured using a radiophotoluminescent glass dosimeter (RGD). The absorbed doses for the pelvis phantom (full scan) ranged from 2.5–4 cGy for kV-CBCT and 4–8 cGy for MV-CBCT. TomoTherapy resulted in a lower dose of approximately 1.3 cGy due to fan-beam. For the head phantom (half scan), the doses ranged from 0.1–0.7 cGy for kV-CBCT and 3–5 cGy for MVCBCT. The results for RGD were similar to ion chamber measurements. It is necessary to decrease the absorbed dose of the organs at risk every time IGRT is applied.Keywords
This publication has 19 references indexed in Scilit:
- Image-Guided Radiotherapy (IGRT) for Prostate Cancer Comparing kV Imaging of Fiducial Markers With Cone Beam Computed Tomography (CBCT)International Journal of Radiation Oncology - Biology - Physics (IJROBP), 2011
- An organ and effective dose study of XVI and OBI cone‐beam CT systemsJournal of Applied Clinical Medical Physics, 2010
- American Society for Therapeutic Radiology and Oncology (ASTRO) and American College of Radiology (ACR) Practice Guidelines for Image-Guided Radiation Therapy (IGRT)International Journal of Radiation Oncology - Biology - Physics (IJROBP), 2010
- Accuracy and Precision of an IGRT SolutionMedical Dosimetry, 2009
- Assessment of patient organ doses and effective doses using the VIP-Man adult male phantom for selected cone-beam CT imaging procedures during image guided radiation therapyRadiation Protection Dosimetry, 2008
- Accurate patient dosimetry of kilovoltage cone‐beam CT in radiation therapyMedical Physics, 2008
- A dose comparison study between XVI®and OBI®CBCT systemsMedical Physics, 2008
- Dose delivered from Varian's CBCT to patients receiving IMRT for prostate cancerPhysics in Medicine & Biology, 2007
- Tomotherapy as a tool in image-guided radiation therapy (IGRT): current clinical experience and outcomesBiomedical Imaging and Intervention Journal, 2007
- AAPM protocol for 40–300 kV x‐ray beam dosimetry in radiotherapy and radiobiologyMedical Physics, 2001