Background Transcatheter aortic valve implantation (TAVI) has been developed to minimize operative morbidity and mortality in high-risk symptomatic patients unfit for open surgery. With the proximity of the aortic valve annulus to the conduction system there is, however, an unknown risk of conduction disturbances necessitating monitoring and often cardiac pacing. Materials and methods We enrolled 50 consecutive patients from January 2007 to 2008 in our prospective evaluation of conduction disturbances measured by surface and intracardiac ECG recordings. Baseline parameters, procedural characteristics as well as twelve-lead surface ECG and intracardiac conduction times were revealed pre-interventionally, after TAVI and at 7-day follow-up. Results TAVI was performed successfully in all patients. During 7 days of follow-up the rate for first-degree AV block raised from 14% at baseline to 44% at day 7 (p < 0.001), while rates for type II second- and third-degree were 0 versus 8% (p < 0.001) and 0 versus 12% (p < 0.001), respectively. Similarly, the prevalence of new left bundle branch block (LBBB) rose from 2 to 54% (p < 0.001). Intracardiac measurements revealed a prolongation of both AH and HV interval from 123.7 ± 41.6 to 136.6 ± 40.5 ms (p < 0.001) and from 54.8 ± 11.7 to 71.4 ± 20.0 ms (p < 0.001), respectively. Pacemaker implantation at a mean follow-up of 4.8 ± 1.2 days was subsequently performed in 23 patients (46%) due to complete AV block (12%) and type II second-degree AV block (8%) while another 13 patients (26%) received a pacemaker for the combination of new LBBB with marked HV prolongation. The high rate of first-degree AV block was primarily driven by an increase in HV interval. Conclusion Cardiac conduction disturbances were common in the early experience with CoreValve implantation necessitating close surveillance for at least 1 week.Keywords
This publication has 28 references indexed in Scilit:
- Transcatheter aortic valve implantation: first results from a multi-centre real-world registryEuropean Heart Journal, 2010
- 2008 Focused Update Incorporated Into the ACC/AHA 2006 Guidelines for the Management of Patients With Valvular Heart DiseaseJACC, 2008
- Transapical minimally invasive aortic valve implantation; the initial 50 patients☆European Journal of Cardio-Thoracic Surgery, 2008
- Transcatheter valve implantation for patients with aortic stenosis: a position statement from the European Association of Cardio-Thoracic Surgery (EACTS) and the European Society of Cardiology (ESC), in collaboration with the European Association of Percutaneous Cardiovascular Interventions (EAPCI)European Heart Journal, 2008
- Clinical Profile and Natural History of 453 Nonsurgically Managed Patients With Severe Aortic StenosisThe Annals of Thoracic Surgery, 2006
- Percutaneous Implantation of the CoreValve Self-Expanding Valve Prosthesis in High-Risk Patients With Aortic Valve DiseaseCirculation, 2006
- Guidelines on the management of valvular heart disease: The Task Force on the Management of Valvular Heart Disease of the European Society of CardiologyEuropean Heart Journal, 2006
- Prognostic significance of newly acquired bundle branch block after aortic valve replacementThe American Journal of Cardiology, 2004
- Prognostic value of infranodal conduction time in patients with chronic bundle branch block.Circulation, 1977
- Syncope and sudden death in aortic stenosisThe American Journal of Cardiology, 1969