The chloride concentration of copper‐refining electrolyte is correlated with the cathode polarization and also with the grain size and the hardness of the copper deposit. It is shown that the curves have a break at the chloride concentration of about 15 mg./L. The variation of the cathode polarization is explained on the assumption that the electrochemical reaction
Cu
+
+
+
e
⇄
Cu
+
is a slow process and that the electrochemical reaction
Cu
+
+
+
2
Cl
−
+
e
→
CuCl
2
−
may take place. The variations of the hardness and the grain size are explained accordingly by the polarization phenomena.