Magnetic Resonance-Based Attenuation Correction and Scatter Correction in Neurological Positron Emission Tomography/Magnetic Resonance Imaging—Current Status With Emerging Applications
Open Access
- 29 January 2020
- journal article
- review article
- Published by Frontiers Media SA in Frontiers in Physics
- Vol. 7
Abstract
In this review, we will summarize the past and current state-of-the-art developments in attenuation and scatter correction approaches for hybrid positron emission tomography (PET) and magnetic resonance (MR) imaging. The current status of the methodological advances for producing accurate attenuation and scatter corrections on PET/MR systems are described, in addition to emerging clinical and research applications. Future prospects and potential applications that benefit from accurate data corrections to improve the quantitative accuracy and clinical applicability of PET/MR are also discussed. Novel clinical and research applications where improved attenuation and scatter correction methods are beneficial are highlighted.Keywords
Funding Information
- Turun Yliopistollinen Keskussairaala (ERVA-project, number 13236)
- Research Council of Finland (269977)
This publication has 207 references indexed in Scilit:
- MRI for attenuation correction in PET: methods and challengesMagnetic Resonance Materials in Physics, Biology and Medicine, 2012
- Evaluation of an attenuation correction method for PET/MR imaging of the head based on substitute CT imagesMagnetic Resonance Materials in Physics, Biology and Medicine, 2012
- Challenges and current methods for attenuation correction in PET/MRMagnetic Resonance Materials in Physics, Biology and Medicine, 2012
- Conversion of arterial input functions for dual pharmacokinetic modeling using Gd‐DTPA/MRI and 18F‐FDG/PETMagnetic Resonance in Medicine, 2012
- MRI-Based Attenuation Correction for Hybrid PET/MRI Systems: A 4-Class Tissue Segmentation Technique Using a Combined Ultrashort-Echo-Time/Dixon MRI SequenceJournal of Nuclear Medicine, 2012
- Performance Measurements of the Siemens mMR Integrated Whole-Body PET/MR ScannerJournal of Nuclear Medicine, 2011
- Why is TOF PET reconstruction a more robust method in the presence of inconsistent data?Physics in Medicine & Biology, 2010
- Model-based scatter correction for fully 3D PETPhysics in Medicine & Biology, 1996
- Effects of scatter on model parameter estimates in 3D PET studies of the human brainIEEE Transactions on Nuclear Science, 1995
- Object shape dependent scatter simulations for PETIEEE Transactions on Nuclear Science, 1991