Evaluation of Basis Function and Linear Least Squares Methods for Generating Parametric Blood Flow Images Using 15O-Water and Positron Emission Tomography
- 1 July 2005
- journal article
- research article
- Published by Springer Nature in Molecular Imaging and Biology
- Vol. 7 (4) , 273-285
Abstract
Parametric analysis of 15O-water positron emission tomography (PET) studies allows determination of blood flow (BF), perfusable tissue fraction (PTF), and volume of distribution (V d) with high spatial resolution. In this paper the performance of basis function and linear least squares methods for generating parametric flow data were evaluated. Monte Carlo simulations were performed using typical perfusion values for brain, tumor, and heart. Clinical evaluation was performed using seven cerebral and 10 myocardial 15O-water PET studies. Basis function (BFM), linear least squares (LLS), and generalized linear least squares (GLLS) methods were used to calculate BF, PTF, or V d. Monte Carlo simulations and human studies showed that, for low BF values (2 ml/min/ml), use of BFM provided more accurate V d compared with (G)LLS. In general, BFM provided the most accurate estimates of BF, PTF, and V d.Keywords
This publication has 42 references indexed in Scilit:
- The ECAT HRRT: performance and first clinical application of the new high resolution research tomographIEEE Transactions on Nuclear Science, 2002
- Measuring tumor blood flow with H215O: practical considerationsNuclear Medicine and Biology, 2000
- Quantitation of Regional Cerebral Blood Flow Corrected for Partial Volume Effect Using O-15 Water and PET: I. Theory, Error Analysis, and Stereologic ComparisonJournal of Cerebral Blood Flow & Metabolism, 2000
- Performance evaluation of the whole-body PET scanner ECAT EXACT HR/sup +/ following the IEC standardIEEE Transactions on Nuclear Science, 1997
- Cerebral [15O]Water Clearance in Humans Determined by PET: I. Theory and Normal ValuesJournal of Cerebral Blood Flow & Metabolism, 1996
- Measurement of regional myocardial blood flow using C 15 O 2 and positron emission tomography: comparison of tracer modelsClinical Physics and Physiological Measurement, 1992
- Weighted Integration Method for Local Cerebral Blood Flow Measurements with Positron Emission TomographyJournal of Cerebral Blood Flow & Metabolism, 1986
- Quantification of regional myocardial blood flow in vivo with H215O.Circulation, 1984
- In vivo measurements of regional cerebral blood flow and blood volume in patients with brain tumours using positron emission tomographyActa Neurochirurgica, 1983
- Measurement of Local Blood Flow and Distribution Volume with Short-Lived Isotopes: A General Input TechniqueJournal of Cerebral Blood Flow & Metabolism, 1982