Development of a protocol to measure volatile organic compounds in human breath: a comparison of rebreathing and on-line single exhalations using proton transfer reaction mass spectrometry
Authors:
- M E O'HAraMOM E O'HAra
- S O'HEhirSOS O'HEhir
- S GreenSGS Green
- C A MayhewCMC A Mayhew
- 11 February 2008
- journal article
- research article
- Published by IOP Publishing in Physiological Measurement
- Vol. 29 (3) , 309-330
Abstract
Analysis of volatile organic compounds (VOCs) on human breath has great potential as a non-invasive diagnostic technique. It is, therefore, surprising that no single, standard procedure has evolved for breath sampling. Here we present a novel repeated-cycle isothermal rebreathing method, where one cycle comprises five rebreaths, which could be adopted for breath analysis of VOCs. For demonstration purposes, we present measurements of three common breath VOCs: isoprene, acetone and methanol. Their concentrations measured in breath are shown to increase with number of rebreaths until a plateau value is reached by at least 20 rebreaths. The average ratio of plateau concentration to single mixed expired breath concentration was found to be 1.92 +/- 0.57 for isoprene, 1.25 +/- 0.13 for acetone and 1.12 +/- 0.12 for methanol (mean +/- standard deviation). Measurements from on-line single exhalations are presented which demonstrate a positive slope in the time-dependent expirograms of isoprene and acetone. The slope of the isoprene expirogram is persistently linear and the end-expired concentration of isoprene is highly variable in the same subject depending on the duration of exhalation. End-expired values of acetone are not as sensitive to the length of exhalation, and are the same to within measurement uncertainty for any duration of exhalation for any subject. It is concluded that uncontrolled single on-line exhalations are not suitable for the reliable measurement of isoprene in the breath and that rebreathing can be the basis of an easily tolerated protocol for the reliable collection of breath samples.Keywords
This publication has 64 references indexed in Scilit:
- The Impact of Breathing Pattern and Lung Size on the Alcohol Breath TestAnnals of Biomedical Engineering, 2006
- Measurements of volatile organic compounds in the earth's atmosphere using proton‐transfer‐reaction mass spectrometryMass Spectrometry Reviews, 2006
- Detection of Lung Cancer by Sensor Array Analyses of Exhaled BreathAmerican Journal of Respiratory and Critical Care Medicine, 2005
- Selected ion flow tube mass spectrometry (SIFT‐MS) for on‐line trace gas analysisMass Spectrometry Reviews, 2004
- Diagnostic potential of breath analysis—focus on volatile organic compoundsClinica Chimica Acta, 2004
- On-line monitoring of volatile organic compounds at pptv levels by means of proton-transfer-reaction mass spectrometry (PTR-MS) medical applications, food control and environmental researchInternational Journal of Mass Spectrometry and Ion Processes, 1998
- Isoprene and sleepLife Sciences, 1989
- Quantitative measurements of the alcohol concentration and the temperature of breath during a prolonged exhalationActa Physiologica Scandinavica, 1982
- Isoprene, an endogenous constituent of human alveolar air with a diurnal pattern of excretionLife Sciences, 1978
- Aceton in der Atemluft und Ketone im Venenblut bei vollständigem Fasten normal- und übergewichtiger PersonenZeitschrift für Die Gesamte Experimentelle Medizin, 1975