A method for in situ absolute DD yield calibration of neutron time-of-flight detectors on OMEGA using CR-39-based proton detectors
- 1 May 2015
- journal article
- conference paper
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 86 (5) , 053506
Abstract
Neutron time of flight (nTOF) detectors are used routinely to measure the absolute DD neutron yield at OMEGA. To check the DD yield calibration of these detectors, originally calibrated using indium activation systems, which in turn were cross-calibrated to NOVA nTOF detectors in the early 1990s, a direct in situ calibration method using CR-39 range filter proton detectors has been successfully developed. By measuring DD neutron and proton yields from a series of exploding pusher implosions at OMEGA, a yield calibration coefficient of 1.09 ± 0.02 (relative to the previous coefficient) was determined for the 3m nTOF detector. In addition, comparison of these and other shots indicates that significant reduction in charged particle flux anisotropies is achieved when bang time occurs significantly (on the order of 500 ps) after the trailing edge of the laser pulse. This is an important observation as the main source of the yield calibration error is due to particle anisotropies caused by field effects. The results indicate that the CR-39-nTOF in situ calibration method can serve as a valuable technique for calibrating and reducing the uncertainty in the DD absolute yield calibration of nTOF detector systems on OMEGA, the National Ignition Facility, and laser megajoule.Keywords
Funding Information
- Fusion Science Center at the University of Rochester (415023-G)
- Laboratory for Laser Energetics (412160-001G)
This publication has 41 references indexed in Scilit:
- The National Ignition Facility neutron time-of-flight system and its initial performance (invited)Review of Scientific Instruments, 2010
- The National Ignition Facility: enabling fusion ignition for the 21st centuryNuclear Fusion, 2004
- Prototypes of National Ignition Facility neutron time-of-flight detectors tested on OMEGAReview of Scientific Instruments, 2004
- Initial performance results of the OMEGA laser systemOptics Communications, 1997
- Ion-temperature measurement of indirectly driven implosions using a geometry-compensated neutron time-of-flight detectorReview of Scientific Instruments, 1995
- Development of a geometry-compensated neutron time-of-flight detector for ICF applications with approximately 200 ps time responseReview of Scientific Instruments, 1992
- Measurement of fuel ion temperatures in ICF implosions using current-mode neutron time-of-flight detectorsReview of Scientific Instruments, 1990
- Detector distance selection for neutron time-of-flight temperature measurementsReview of Scientific Instruments, 1990
- Neutron yield measurements with current-mode neutron time-of-flight detectors (abstract)Review of Scientific Instruments, 1988
- Laser fusion ion temperatures determined by neutron time-of-flight techniquesApplied Physics Letters, 1977