Wind pressure characteristics of elliptical retractable dome roofs
Open Access
- 30 June 2021
- journal article
- research article
- Published by Taylor & Francis in Journal of Asian Architecture and Building Engineering
- Vol. 21 (4) , 1561-1577
Abstract
This study investigated the wind pressure characteristics of an elliptical plan retractable dome roof. Wind tunnel experiments were performed on elliptical dome roofs with varying wall height-to-span ratios (0.1–0.5) and opening ratios (0, 10, 30, and 50 %), where the opening ratio was defined as the ratio of the open area of the roof to the total area of the roof. The resulting peak pressure coefficients of the closed dome roof were then compared with those of the Japanese wind load code (AIJ-RLB ( 2015 )) as there are no current peak pressure coefficients for the cladding design code of elliptical dome roofs. The resulting peak pressure coefficients for each elliptical retractable dome roof opening ratio were also compared with those for the cladding design of spherical retractable domes proposed in previous research. Finally, based on the results of the comparative analysis, negative and positive peak pressure coefficients were proposed for the cladding design of elliptical retractable dome roofs.Keywords
Funding Information
- Architecture & Urban Development Research Program
- the Architecture & Urban Development Research Program funded by the Ministry of Land, Infrastructure, and Transport of the Korean Government (20AUDP-B100343-06)
- the National Research Foundation of Korea (NRF-2019R1A2C1086485)
This publication has 8 references indexed in Scilit:
- Analysis of External Peak Pressure Coefficients for Cladding in Elliptical Retractable Dome Roof by Wind Tunnel TestJournal of the Korean Association for Spatial Structures, 2020
- Characteristics of wind pressures on retractable dome roofs and external peak pressure coefficients for cladding designJournal of Wind Engineering and Industrial Aerodynamics, 2019
- Comparison of Wind Pressure Coefficient and Wind Load Standard for Cladding in a Retractable Dome Roof by Wind Tunnel TestJournal of the Korean Association for Spatial Structures, 2018
- Design pressure coefficients for circular and elliptical plan structures with hyperbolic paraboloid roofEngineering Structures, 2017
- Wind tunnel tests on hyperbolic paraboloid roofs with elliptical plane shapesEngineering Structures, 2012
- Mean and fluctuating wind loads on rough and smooth parabolic domesJournal of Wind Engineering and Industrial Aerodynamics, 2000
- A refined working approach to the assessment of wind loads for equivalent static designJournal of Wind Engineering and Industrial Aerodynamics, 1980
- Efficient methods of extreme-value methodology1974