Bone alterations at implant‐supported FDPs in relation to inter‐unit distances: a 5‐year radiographic study
Authors:
- 7 June 2010
- journal article
- Published by Wiley in Clinical Oral Implants Research
- Vol. 21 (7) , 735-740
Abstract
Objectives: The aim of this 5‐year study was to longitudinally evaluate bone alterations around implants with a conical implant–abutment interface in relation to implant–tooth and inter–implant distances.Material and methods: The patient sample comprised 43 partially dentate patients with a total of 48 implant‐supported fixed dental prostheses (FDPs) supported by 130 Astra Tech® implants. Following FDP placement (baseline), the patients were enrolled in an individually designed supportive care program. Radiographic examinations were performed at the time of FDP installation, 1 and 5 years of follow‐up. Variables regarding implant position and proximal bone topography at tooth/implant units (n=36) and implant/implant units (n=67) were assessed with the use of a software program after scanning of the radiographs.Results: At tooth/implant units, the mean 5‐year marginal bone loss at the tooth, the implant and the mid‐proximal bone crest was 0.1, 0.4 and 0.2 mm, respectively. The mean longitudinal bone loss at the implant/implant units was 0.5 mm at the implants and 0.3 mm mid‐proximally. Multilevel regression analysis revealed that at implant/implant units, the change in the bone‐to‐implant contact level was a significant predictor with regard to the 5‐year mid‐proximal bone‐level change, whereas the horizontal inter‐unit distance showed a borderline significance (P=0.052). At tooth/implant units, no statistically significant associations were identified.Conclusions: The results of this 5‐year study revealed differences between inter‐implant and tooth–implant proximal areas with regard to bone crest alterations and associated factors. To cite this article: Chang M, Wennström JL. Bone alterations at implant‐supported FDPs in relation to inter‐unit distances: a 5‐year radiographic study. Clin. Oral Impl. Res. 21, 2010; 735–740. doi: 10.1111/j.1600‐0501.2009.01893.xKeywords
This publication has 17 references indexed in Scilit:
- Inter‐Implant Bone Height Changes in Anterior Maxillary Immediate and Non‐Immediate Adjacent Dental ImplantsJournal of Periodontology, 2007
- The Effects of Interimplant Distances on Papilla Formation and Crestal Resorption in Implants With a Morse Cone Connection and a Platform Switch: A Histomorphometric Study in DogsJournal of Periodontology, 2006
- Bone reactions to longstanding functional load at implants: an experimental study in dogsJournal of Clinical Periodontology, 2005
- Interimplant Distance and Crestal Bone Resorption: A Histologic Study in the Canine MandibleClinical Implant Dentistry and Related Research, 2004
- Oral rehabilitation with implant‐supported fixed partial dentures in periodontitis‐susceptible subjectsJournal of Clinical Periodontology, 2004
- The effect of dental implant spacing on peri‐implant bone using the rabbit (oryctolagus cuniculus) tibia modelJournal of Prosthodontics, 2001
- A computer‐assisted measurement technique to assess bone proximal to oral implants on intraoral radiographsClinical Oral Implants Research, 2001
- The implant neck: smooth or provided with retention elements. A biomechanical approach.Clinical Oral Implants Research, 1999
- Recession of the soft tissue margin at oral implants. A 2‐year longitudinal prospective study.Clinical Oral Implants Research, 1996
- Radiological evaluation of marginal bone loss at tooth surfaces facing single Brånemark implantsClinical Oral Implants Research, 1993