A novel MRI‐compatible brain ventricle phantom for validation of segmentation and volumetry methods
Authors:
- Amanda F. KhanAKAmanda F. Khan
- Robert M. TaRTRobert M. Ta
- Michael J. BorrieMBMichael J. Borrie
- Robert BarthaRBRobert Bartha
Open Access
- 7 March 2012
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 36 (2) , 476-482
Abstract
Purpose: To create a standardized, MRI‐compatible, life‐sized phantom of the brain ventricles to evaluate ventricle segmentation methods using T1‐weighted MRI. An objective phantom is needed to test the many different segmentation programs currently used to measure ventricle volumes in patients with Alzheimer's disease.Materials and Methods: A ventricle model was constructed from polycarbonate using a digital mesh of the ventricles created from the 3 Tesla (T) MRI of a subject with Alzheimer's disease. The ventricle was placed in a brain mold and surrounded with material composed of 2% agar in water, 0.01% NaCl and 0.0375 mM gadopentetate dimeglumine to match the signal intensity properties of brain tissue in 3T T1‐weighted MRI. The 3T T1‐weighted images of the phantom were acquired and ventricle segmentation software was used to measure ventricle volume.Results: The images acquired of the phantom successfully replicated in vivo signal intensity differences between the ventricle and surrounding tissue in T1‐weighted images and were robust to segmentation. The ventricle volume was quantified to 99% accuracy at 1‐mm voxel size.Conclusion: The phantom represents a simple, realistic and objective method to test the accuracy of lateral ventricle segmentation methods and we project it can be extended to other anatomical structures. J. Magn. Reson. Imaging 2012;36:476–482.Keywords
This publication has 20 references indexed in Scilit:
- An MRI digital brain phantom for validation of segmentation methodsMedical Image Analysis, 2011
- Hippocampal, caudate, and ventricular changes in Parkinson's disease with and without dementiaMovement Disorders, 2010
- High-throughput, Fully Automated Volumetry for Prediction of MMSE and CDR Decline in Mild Cognitive ImpairmentAlzheimer Disease & Associated Disorders, 2009
- Ventricular enlargement as a possible measure of Alzheimer's disease progression validated using the Alzheimer's disease neuroimaging initiative databaseBrain, 2008
- Ventricular Enlargement after Moderate or Severe Head Injury: A Frequent and Neglected ProblemJournal of Neurotrauma, 2005
- Composition of MRI phantom equivalent to human tissuesMedical Physics, 2005
- Automatic volumetric measurement of lateral ventricles on magnetic resonance images with correction of partial volume effectsJournal of Magnetic Resonance Imaging, 2002
- Design and construction of a realistic digital brain phantomIEEE Transactions on Medical Imaging, 1998
- 3-D phantom to simulate cerebral blood flow and metabolic images for PETIEEE Transactions on Nuclear Science, 1990
- An MRI phantom material for quantitative relaxometryMagnetic Resonance in Medicine, 1987