SPECT/CT tracer uptake is influenced by tunnel orientation and position of the femoral and tibial ACL graft insertion site
- 11 November 2012
- journal article
- research article
- Published by Springer Nature in International Orthopaedics
- Vol. 37 (2) , 301-309
Abstract
Purpose SPECT/CT is a hybrid imaging modality, which combines a 3D scintigraphy (SPECT) and a conventional computerised tomography (CT). SPECT/CT allows accurate anatomical localisation of metabolic tracer activity. It allows the correlation of surgical factors such as tunnel position and orientation with mechanical alignment, clinical outcome and biological factors. The purpose of this study was to investigate whether the SPECT/CT tracer uptake (intensity and distribution) correlates with the stability and laxity of the knee joint and the position and orientation of the tibial and femoral tunnels in patients after anterior cruciate ligament (ACL) reconstruction. Methods A consecutive series of knees (n = 66), with symptoms of pain and/or instability after ACL reconstruction were prospectively evaluated using clinical examination and 99mTc-HDP-SPECT/CT. Clinical laxity testing was performed using the Rolimeter (Ormed, Freiburg, Germany) including Lachman testing (0–2 mm, 3–5 mm, 6–10 mm, >10 mm), anterior drawer test (0–2 mm, 3–5 mm, 6–10 mm, >10 mm), pivot shift test (positive versus negative) and patient-based subjective instability (yes versus no). For analysis of SPECT/CT tracer uptake a previously validated SPECT/CT localisation scheme consisting of 17 tibial, nine femoral and four patellar regions on standardised axial, coronal, and sagittal slices was used. The tracer activity on SPECT/CT was localised and recorded using a 3D volumetric and quantitative analysis software. Mean, standard deviation, minimum and maximum of grading for each area of the localisation scheme were recorded. The position and orientation of the tibial and femoral tunnel was assessed using a previously published method on 3D-CT. Results Correlation of instability, pivot shift as well as clinical laxity testing with 99mTc-HDP-SPECT/CT tracer uptake intensity and distribution showed no significant correlation. 99mTc-HDP-SPECT/CT tracer uptake correlated significantly with the position and orientation of the ACL graft. A more horizontal femoral graft position showed significantly increased tracer uptake within the superior and posterior femoral regions. A more posteriorly-placed femoral insertion site showed significantly more tracer uptake within the femoral and tibial tunnel regions. A more vertical or a less medial tibial tunnel orientation showed significant increased uptake within the tibial and femoral tunnel regions. A more anterior tibial tunnel position showed significantly more tracer uptake in the femoral and tibial tunnel regions as well as the entire tibiofemoral joint. Conclusions SPECT/CT tracer uptake intensity and distribution showed a significant correlation with the femoral and tibial tunnel position and orientation in patients with symptomatic knees after ACL reconstruction. No correlation was found with stability or clinical laxity. SPECT/CT tracer uptake distribution has the potential to give us important information on joint homeostasis and remodelling after ACL reconstruction. It might help to predict ACL graft failure and improve our surgical ACL reconstruction technique in finding the optimal tunnel and graft position and orientation.Keywords
This publication has 23 references indexed in Scilit:
- Transtibial ACL reconstruction technique fails to position drill tunnels anatomically in vivo 3D CT studyKnee Surgery, Sports Traumatology, Arthroscopy, 2011
- Impact of Tibial and Femoral Tunnel Position on Clinical Results After Anterior Cruciate Ligament ReconstructionArthroscopy, 2010
- ACL graft re‐rupture after double‐bundle reconstruction: factors that influence the intra‐articular pattern of injuryKnee Surgery, Sports Traumatology, Arthroscopy, 2010
- Painful knee joint after ACL reconstruction using biodegradable interference screws- SPECT/CT a valuable diagnostic tool? A case reportBMC Sports Science, Medicine and Rehabilitation, 2010
- Revision Anterior Cruciate Ligament ReconstructionThe American Journal of Sports Medicine, 2010
- Causes for failure of ACL reconstruction and influence of meniscectomies after revisionKnee Surgery, Sports Traumatology, Arthroscopy, 2010
- The Location of Femoral and Tibial Tunnels in Anatomic Double-Bundle Anterior Cruciate Ligament Reconstruction Analyzed by Three-Dimensional Computed Tomography ModelsJournal of Bone and Joint Surgery, 2010
- Combined single‐photon emission computerized tomography and conventional computerized tomography (SPECT/CT): clinical value for the knee surgeons?Knee Surgery, Sports Traumatology, Arthroscopy, 2009
- Validation of the position of the femoral tunnels in anatomic double‐bundle ACL reconstruction with 3‐D CT scanKnee Surgery, Sports Traumatology, Arthroscopy, 2009
- Anterior Cruciate Ligament Insertions on the Tibia and Femur and Their Relationships to Critical Bony Landmarks Using High-Resolution Volume-Rendering Computed TomographyThe American Journal of Sports Medicine, 2008