Vital Signal Detection Using Multi-Radar for Reductions in Body Movement Effects
Open Access
Abstract
Vital signal detection using multiple radars is proposed to reduce the signal degradation from a subject’s body movement. The phase variation in the transceiving signals of continuous-wave radar due to respiration and heartbeat is generated by the body surface movement of the organs monitored in the line-of-sight (LOS) of the radar. The body movement signals obtained by two adjacent radars can be assumed to be the same over a certain distance. However, the vital signals are different in each radar, and each radar has a different LOS because of the asymmetric movement of lungs and heart. The proposed method uses two adjacent radars with different LOS to obtain correlated signals that reinforce the difference in the asymmetrical movement of the organs. The correlated signals can improve the signal-to-noise ratio in vital signal detection because of a reduction in the body movement effect. Two radars at different frequencies in the 5.8 GHz band are implemented to reduce direct signal coupling. Measurement results using the radars arranged at angles of 30°, 45°, and 60° showed that the proposed method can detect the vital signals with a mean accuracy of 97.8% for the subject moving at a maximum velocity of 53.4 mm/s.Keywords
Funding Information
- Yeungnam University (220A380046)
This publication has 30 references indexed in Scilit:
- A Self- and Mutually Injection-Locked Radar System for Monitoring Vital Signs in Real Time With Random Body Movement CancellationIEEE Transactions on Microwave Theory and Techniques, 2016
- Wireless Hand Gesture Recognition Based on Continuous-Wave Doppler Radar SensorsIEEE Transactions on Microwave Theory and Techniques, 2016
- Single-Antenna Doppler Radars Using Self and Mutual Injection Locking for Vital Sign Detection With Random Body Movement CancellationIEEE Transactions on Microwave Theory and Techniques, 2011
- Random Body Movement Cancellation in Doppler Radar Vital Sign DetectionIEEE Transactions on Microwave Theory and Techniques, 2008
- Arctangent Demodulation With DC Offset Compensation in Quadrature Doppler Radar Receiver SystemsIEEE Transactions on Microwave Theory and Techniques, 2007
- Experiment and Spectral Analysis of a Low-Power $Ka$-Band Heartbeat Detector Measuring From Four Sides of a Human BodyIEEE Transactions on Microwave Theory and Techniques, 2006
- Evaluation of Chest Motion and Volumetry During the Breathing Cycle by Dynamic MRI in Healthy SubjectsInvestigative Radiology, 2004
- Chest wall motion during tidal breathingJournal of Applied Physiology, 1997
- Three-dimensional reconstruction of cardiac displacement patterns on the chest wall during the P, QRS and T-segments of the ECG by laser speckle inteferometryMedical & Biological Engineering & Computing, 1989
- Reconstruction of Cardiac Displacement Patterns on the Chest Wall by Laser Speckle InterferometryIEEE Transactions on Medical Imaging, 1985