The aim of this study was to assess the central macular imaging captured with an optical biometer based on full-eye-length Swept-Source OCT (SS-OCT) scan as a screening strategy for identifying macular diseases in patients scheduled for cataract surgery. 1,114 eyes of 749 consecutive patients underwent a biometrical examination with IOLMaster 700 SS-OCT technology (Carl Zeiss) and conventional Spectral-Domain OCT (SD-OCT) (Spectralis OCT, Heidelberg) device analysis on the same day. Seven examiners graded the scans individually in a full-masked mode. Twenty-five eyes were excluded for media opacities. Among the 1,089 included eyes, statistical analysis revealed a mean Kendall’s Coefficient of 0.83 (range 0.76–0.89). A logistic regression model demonstrated a highly significant correlation (p < 0.001) between the coefficient of concordance and SD-OCT imaging. Intraobserver reproducibility was 0.89 (range 0.86–0.91). Optical biometer SS-OCT scans showed a mean sensitivity of 0.81 and a mean specificity of 0.84. The positive and negative predictive value detected was 0.78 and 0.86, respectively. In order to predict the risk of reduced visual recovery, especially in cases of retinal pathology, optical biometer with SS-OCT scan has proven to be a useful modality for detecting macular structural abnormalities in patients undergoing cataract surgery. Conventional SD-OCT remains mandatory to confirm the presumed diagnosis.Keywords
This publication has 16 references indexed in Scilit:
- Macular disease detection with a swept-source optical coherence tomography-based biometry device in patients scheduled for cataract surgeryJournal of Cataract & Refractive Surgery, 2016
- Biometry measurements using a new large-coherence–length swept-source optical coherence tomographerJournal of Cataract & Refractive Surgery, 2016
- CORRELATION OF FOVEAL AVASCULAR ZONE SIZE WITH FOVEAL MORPHOLOGY IN NORMAL EYES USING OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHYRetina, 2015
- Foveal Pit Morphology Evaluation during Optical Biometry Measurements using a Full-Eye-Length Swept-Source OCT Scan Biometer PrototypeEuropean Journal of Ophthalmology, 2015
- Perioperative retina evaluation of the cataract surgery patientCurrent Opinion in Ophthalmology, 2015
- Comparison of choroidal thicknesses using swept source and spectral domain optical coherence tomography in diseased and normal eyesBritish Journal of Ophthalmology, 2014
- Rising Cataract Surgery Rates: Demand and SupplyOphthalmology, 2014
- Impact of clinical and patient‐reported outcomes on patient satisfaction with cataract extractionHealth Expectations, 2012
- Coefficient of Concordance2010