High-Frame-Rate Speckle-Tracking Echocardiography
Authors:
- Philippe JoosPJPhilippe Joos
- Jonathan PoreeJPJonathan Poree
- Herve LiebgottHLHerve Liebgott
- Didier VrayDVDidier Vray
- Mathilde BaudetMBMathilde Baudet
- Julia FaurieJFJulia Faurie
- Francois TournouxFTFrancois Tournoux
- Guy CloutierGCGuy Cloutier
- Barbara NicolasBNBarbara Nicolas
- Damien GarciaDGDamien Garcia
- 27 February 2018
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 65 (5) , 720-728
Abstract
Conventional echocardiography is the leading modality for noninvasive cardiac imaging. It has been recently illustrated that high-frame-rate echocardiography using diverging waves could improve cardiac assessment. The spatial resolution and contrast associated with this method are commonly improved by coherent compounding of steered beams. However, owing to fast tissue velocities in the myocardium, the summation process of successive diverging waves can lead to destructive interferences if motion compensation (MoCo) is not considered. Coherent compounding methods based on MoCo have demonstrated their potential to provide high-contrast B-mode cardiac images. Ultrafast speckle-tracking echocardiography (STE) based on common speckle-tracking algorithms could substantially benefit from this original approach. In this paper, we applied STE on high-frame-rate B-mode images obtained with a specific MoCo technique to quantify the 2-D motion and tissue velocities of the left ventricle. The method was first validated in vitro and then evaluated in vivo in the four-chamber view of 10 volunteers. High-contrast high-resolution B-mode images were constructed at 500 frames/s. The sequences were generated with a Verasonics scanner and a 2.5-MHz phased array. The 2-D motion was estimated with standard cross correlation combined with three different subpixel adjustment techniques. The estimated in vitro velocity vectors derived from STE were consistent with the expected values, with normalized errors ranging from 4% to 12% in the radial direction and from 10% to 20% in the cross-range direction. Global longitudinal strain of the left ventricle was also obtained from STE in 10 subjects and compared to the results provided by a clinical scanner: group means were not statistically different ($p$ value = 0.33). The in vitro and in vivo results showed that MoCo enables preservation of the myocardial speckles and in turn allows high-frame-rate STE.Keywords
Funding Information
- Fonds de recherche du Québec-Nature et technologies
- LABEX Center Lyonnais d’Acoustique
- ANR-10 et Simulation (PRIMES) (ANR-10-LABX-0063)
- Investissements d’Avenir (ANR-11-IDEX-0007)
- Région Rhône-Alpes (Explora’Pro, Explora’Doc)
- Natural Sciences and Engineering Research Council of Canada (RGPAS-477914-2015, RGPIN-04217-2015)
- Fonds de recherche du Québec-Nature et technologies (2016-PR-189822)
- French Federation of Cardiology
This publication has 48 references indexed in Scilit:
- Characterisation of carotid plaques with ultrasound elastography: feasibility and correlation with high-resolution magnetic resonance imagingEuropean Radiology, 2013
- Normal Ranges of Left Ventricular Strain: A Meta-AnalysisJournal of the American Society of Echocardiography, 2013
- Echocardiographic Assessment of Myocardial StrainJACC, 2011
- High-frame-rate echocardiography using diverging transmit beams and parallel receive beamformingJournal of Medical Ultrasonics, 2011
- On the Potential of the Lagrangian Estimator for Endovascular Ultrasound Elastography: In Vivo Human Coronary Artery StudyUltrasound in Medicine & Biology, 2007
- Global longitudinal strain: a novel index of left ventricular systolic functionJournal of the American Society of Echocardiography, 2004
- A subspace identification extension to the phase correlation methodIEEE Transactions on Medical Imaging, 2003
- Stress echocardiographyHeart, 2003
- Extension of phase correlation to subpixel registrationIEEE Transactions on Image Processing, 2002
- Explososcan: A parallel processing technique for high speed ultrasound imaging with linear phased arraysThe Journal of the Acoustical Society of America, 1984