Toward a Practical Impedimetric Biosensor: A Micro-Gap Parallel Plate Electrode Structure That Suppresses Unexpected Device-to-Device Variations
Open Access
- 23 March 2022
- journal article
- research article
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 7 (13) , 11017-11022
Abstract
We propose a rational electrode design concept for affinity biosensors based on electrochemical impedance spectroscopy to substantially suppress unexpected device-to-device variations. On the basis that the uniformity of the current distribution affects the variation, a novel micro-gap parallel plate electrode (PPE) was developed, where two planar electrodes with edges covered with a SiO2 layer were placed face to face. The structure provides a uniform current distribution over the planar electrode surface and maximizes the contribution of the planar electrode surface to sensing. For a comparative study, we also fabricated a micro-structured interdigitated electrode (IDE) that has been widely adopted for high-sensitivity measurement, although its current is highly concentrated on the electrode edge corner. Protein G (PrG) molecules were immobilized on both electrodes to prepare an immunoglobulin G (IgG) biosensor on which the specific binding of PrG–IgG can occur. We demonstrated that the IgG sensor with the PPE has small device-to-device variations, in strong contrast to the sensor with the IDE having large device-to-device variations. The results indicate that the current distribution on the electrode surface is important to fabricating electrochemical impedance spectroscopy biosensors with small device-to-device variations. Furthermore, it was found that the PPE allows ultrasensitive detection, that is, the sensor exhibited a linear range from 1 × 10–13 to 1 × 10–7 mol/L with a detection limit of 1 × 10–14 mol/L, which is a record sensitivity at low concentrations for EIS-based IgG sensors.Keywords
Funding Information
- Ministry of Education, Culture, Sports, Science and Technology
- Japan Society for the Promotion of Science (20K05300)
This publication has 46 references indexed in Scilit:
- On-line sensor calibration transfer among electronic nose instruments for monitoring volatile organic chemicals in indoor air qualitySensors and Actuators B: Chemical, 2011
- Nanoparticle-Enhanced Sensitivity of a Nanogap-Interdigitated Electrode Array Impedimetric BiosensorLangmuir, 2011
- Antibody functionalized interdigitated μ-electrode (IDμE) based impedimetric cortisol biosensorThe Analyst, 2010
- Label-free electrochemical impedance spectroscopy biosensor for the determination of human immunoglobulin GMicrochimica Acta, 2010
- Challenges of Electrochemical Impedance Spectroscopy in Protein BiosensingAnalytical Chemistry, 2009
- Label‐Free Impedance Biosensors: Opportunities and ChallengesElectroanalysis, 2007
- Reflections on the history of electrochemical impedance spectroscopyElectrochimica Acta, 2006
- Protein Biosensors Based on Biofunctionalized Conical Gold NanotubesJournal of the American Chemical Society, 2005
- Characterization and Optimization of Interdigitated Ultramicroelectrode Arrays as Electrochemical Biosensor TransducersElectroanalysis, 2004
- The immunosensors for measurement of 2,4-dichlorophenoxyacetic acid based on electrochemical impedance spectroscopyBioelectrochemistry, 2004