Analysis of heparin oligosaccharides by capillary electrophoresis–negative-ion electrospray ionization mass spectrometry
- 20 June 2016
- journal article
- research article
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 409 (2) , 411-420
Abstract
Most hyphenated analytical approaches that rely on liquid chromatography–MS require relatively long separation times, produce incomplete resolution of oligosaccharide mixtures, use eluents that are incompatible with electrospray ionization, or require oligosaccharide derivatization. Here we demonstrate the analysis of heparin oligosaccharides, including disaccharides, ultralow molecular weight heparin, and a low molecular weight heparin, using a novel electrokinetic pump-based CE–MS coupling eletrospray ion source. Reverse polarity CE separation and negative-mode electrospray ionization were optimized using a volatile methanolic ammonium acetate electrolyte and sheath fluid. The online CE hyphenated negative-ion electrospray ionization MS on an LTQ Orbitrap mass spectrometer was useful in disaccharide compositional analysis and bottom-up and top-down analysis of low molecular weight heparin. The application of this CE–MS method to ultralow molecular heparin suggests that a charge state distribution and the low level of sulfate group loss that is achieved make this method useful for online tandem MS analysis of heparins. Most hyphenated analytical approaches that rely on liquid chromatography–MS require relatively long separation times, produce incomplete resolution of oligosaccharide mixtures, use eluents that are incompatible with electrospray ionization, or require oligosaccharide derivatization. Here we demonstrate the analysis of heparin oligosaccharides, including disaccharides, ultralow molecular weight heparin, and a low molecular weight heparin, using a novel electrokinetic pump-based CE–MS coupling eletrospray ion source. Reverse polarity CE separation and negative-mode electrospray ionization were optimized using a volatile methanolic ammonium acetate electrolyte and sheath fluid. The online CE hyphenated negative-ion electrospray ionization MS on an LTQ Orbitrap mass spectrometer was useful in disaccharide compositional analysis and bottom-up and top-down analysis of low molecular weight heparin. The application of this CE–MS method to ultralow molecular heparin suggests that a charge state distribution and the low level of sulfate group loss that is achieved make this method useful for online tandem MS analysis of heparinsKeywords
Funding Information
- National Institutes of Health (GM103390)
This publication has 30 references indexed in Scilit:
- GlycReSoft: A Software Package for Automated Recognition of Glycans from LC/MS DataPLOS ONE, 2012
- Disaccharide analysis of glycosaminoglycan mixtures by ultra-high-performance liquid chromatography–mass spectrometryJournal of Chromatography A, 2012
- The proteoglycan bikunin has a defined sequenceNature Chemical Biology, 2011
- Ultra-performance ion-pairing liquid chromatography with on-line electrospray ion trap mass spectrometry for heparin disaccharide analysisAnalytical Biochemistry, 2011
- Heparin Mapping Using Heparin Lyases and the Generation of a Novel Low Molecular Weight HeparinJournal of Medicinal Chemistry, 2010
- Simplified capillary electrophoresis nanospray sheath‐flow interface for high efficiency and sensitive peptide analysisRapid Communications in Mass Spectrometry, 2010
- Fell‐Muir Lecture: Proteoglycans and more – from molecules to biologyInternational Journal of Experimental Pathology, 2009
- Lessons learned from the contamination of heparinNatural Product Reports, 2009
- Oversulfated chondroitin sulfate is a contaminant in heparin associated with adverse clinical eventsNature Biotechnology, 2008
- On‐line sheathless capillary electrophoresis/nanoelectrospray ionization‐tandem mass spectrometry for the analysis of glycosaminoglycan oligosaccharidesElectrophoresis, 2004