Abstract
Background: Point Of Care Ultra-Sound (POCUS) is an operator dependent modality. POCUS examinations usually include ‘Eyeballing’ the inspected anatomical structure without conducting accurate measurements due to complexity and insufficient time. Automatic real time measuring tools can make accurate measurements fast and simple and dramatically increase examination reliability while saving the operator much time and effort. In this study we aim to assess three automatic tools which are integrated into the Venue™ device by GE: the automatic ejection fraction, velocity time integral, and inferior vena cava tools in comparison to the gold standard—an examination by a POCUS expert. Methods: A separate study was conducted for each of the three automatic tools. In each study, cardiac views were acquired by a POCUS expert. Relevant measurements were taken by both an auto tool and a POCUS expert who was blinded to the auto tool’s measurement. The agreement between the POCUS expert and the auto tool was measured for both the measurements and the image quality using a Cohen’s Kappa test. Results: All three tools have shown good agreement with the POCUS expert for high quality views: auto LVEF (0.498; p < 0.001), auto IVC (0.536; p = 0.009), and the auto VTI (0.655; p = 0.024). Auto VTI has also shown a good agreement for medium quality clips (0.914; p < 0.001). Image quality agreement was significant for the auto EF and auto IVC tools. Conclusions: The Venue™ show a high agreement with a POCUS expert for high quality views. This shows that auto tools can provide reliable real time assistance in performing accurate measurements, but do not reduce the need of a good image acquisition technique.Keywords
Funding Information
- General Electric
This publication has 29 references indexed in Scilit:
- Make it SIMPLE: enhanced shock management by focused cardiac ultrasoundJournal of Intensive Care, 2016
- Variation in the use of point-of-care ultrasound in general practice in various European countries. Results of a survey among expertsEuropean Journal of General Practice, 2016
- The Diagnostic and Therapeutic Impact of Point-of-Care Ultrasonography in the Intensive Care UnitJournal of Intensive Care Medicine, 2016
- Using Point-of-Care Bedside Ultrasound for Volume Assessment in Early Shock: An Outcome StudyChest, 2016
- Diagnosing Acute Heart Failure in the Emergency Department: A Systematic Review and Meta‐analysisAcademic Emergency Medicine, 2016
- Cardiac Ultrasonography in the critical care setting: a practical approach to asses cardiac function and preload for the “non-cardiologist”Anaesthesiology Intensive Therapy, 2015
- Visual Estimation of Bedside Echocardiographic Ejection Fraction by Emergency PhysiciansWestern Journal of Emergency Medicine, 2014
- Point-of-care multiorgan ultrasonography for the evaluation of undifferentiated hypotension in the emergency departmentIntensive Care Medicine, 2013
- Emergency Department Bedside Ultrasonographic Measurement of the Caval Index for Noninvasive Determination of Low Central Venous PressureAnnals of Emergency Medicine, 2010
- Measuring left ventricular volume and ejection fraction with the biplane Simpson’s methodHeart, 2002